Author: Chris 
Type: Update 
Category: DAQ 
Subject: DAQ troubleshooting 

It looks like the RFM problem started a little after 2am on Saturday morning (attachment 1). It’s subsequent to what I did, but during a time of no apparent activity, either by me or others.

The pattern of errors on c1rfm (attachment 2) looks very much like this one previously reported by Gautam (errors on all IRFM0 ipcs). Maybe the fix described in Koji’s followup will work again (involving hard reboots).

Attachment 1: timeseries.png  191 kB  Uploaded Mon May 16 13:59:58 2022  | Hide | Hide all
timeseries.png
Attachment 2: err.png  44 kB  Uploaded Mon May 16 14:00:08 2022  | Hide | Hide all
err.png