[Paco]
In reply to Koji's questions;
Q1: What is the product number of the broken Kepco?
A1: Kepco JQE 0-25 V 4A (1/4 rack mountable 100 W linear power supply)
Q2: Do you feel the burning smell on this broken kepco?
A2: Not very clearly. It just smells like generic broken electronic, but the fan was already long gone by the time we detected its problem.
Q3: How much current does the +15 VDC line draw from the Sorensen?
A3: The Sorensen current monitor reads 6.3 Amps
Q4: Is there a linear power supply in the market that can handle this much current with some margin?
A4: Probably... but we would have to look around.
Q5: Do we really need a linear power supply there?
A5: Good question, I guess anything that is not contaminating the RF electronics with HF noise (e.g. switching PS) can work?
Q6: Is the same fan problem happening on other Kepcos?
A6: Other fans are on, but at least one or two have the "ill" sound... It may be worthwile to give them maintenance if we can. |