Message ID: 16585
Entry time: Fri Jan 14 11:00:29 2022
In reply to: 16584
Reply to this: 16587
|
Author: |
Anchal |
Type: |
Update |
Category: |
BHD |
Subject: |
PR2 transmission calculation |
|
|
Yeah, I counted the loss from arm cavities as the transmission from ETMs on each bounce. I assumed Michelson to be perfectly aligned to get no light at the dark port. Should I use some other number for the round-trip loss in the arm cavity? |