Message ID: 16558     Entry time: Fri Jan 7 18:28:13 2022     In reply to: 16555     Reply to this: 16560
Author: Koji 
Type: Update 
Category: BHD 
Subject: PR2 Sat Amp has a bad channel 

Leave the unit to me. I can look it at on Mon. For a while, you can take a replacement unit from the electronics stack.

Also: Was this unit tested before? If so, what was the testing result at the time?