Message ID: 16538     Entry time: Sun Jan 2 20:46:46 2022
Author: Koji 
Type: Update 
Category: SUS 
Subject: End SUS Electronics building 

19:00~ Start working on the electronics bench

The following units were tested and ready to be installed. These are the last SUS electronics units and we are now ready to upgrade the end SUS electronics too.

40m End ADC Adapter Unit D2100016 / 2 Units (S2200001 S2200002)

40m End DAC Adapter Unit D2100647/ 2 Units (S2200003 S2200004)

These are placed on Tega's desk together with the vertex DAC adapters

0:30 End work

Attachment 1: PXL_20220103_081133119.jpg  2.590 MB  Uploaded Mon Jan 3 00:28:53 2022  | Hide | Hide all