Fri Dec 10 15:59:23 2021, Paco, Update, BHD, Finished Coil driver (even serial number) units tests
|
Thu Dec 16 12:21:16 2021, Anchal, Update, BHD, Coil driver test failed for S2100619-v1
|
Thu Dec 16 17:41:12 2021, Koji, Update, BHD, Coil driver test failed for S2100619-v1 6x
|
Thu Dec 16 15:32:59 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests
|
Thu Dec 16 17:57:17 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests
|
Mon Dec 20 14:10:56 2021, Anchal, Update, BHD, All coil drivers ready to be used, modified and tested
|
|
Message ID: 16517
Entry time: Thu Dec 16 17:57:17 2021
In reply to: 16514
|
Author: |
Anchal |
Type: |
Update |
Category: |
BHD |
Subject: |
Finished Coil driver (odd serial number) units tests |
|
|
S2100619 was fixed by Koji and it passed the test after that.
|