40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Dec 10 15:59:23 2021, Paco, Update, BHD, Finished Coil driver (even serial number) units tests dc_fail.jpg
    Reply  Thu Dec 16 12:21:16 2021, Anchal, Update, BHD, Coil driver test failed for S2100619-v1 D1100687_S2100619-v1_TF_CH2_Not_Matching.pdf
       Reply  Thu Dec 16 17:41:12 2021, Koji, Update, BHD, Coil driver test failed for S2100619-v1 6x
    Reply  Thu Dec 16 15:32:59 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests 
       Reply  Thu Dec 16 17:57:17 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests 
       Reply  Mon Dec 20 14:10:56 2021, Anchal, Update, BHD, All coil drivers ready to be used, modified and tested 
Message ID: 16516     Entry time: Thu Dec 16 17:41:12 2021     In reply to: 16512
Author: Koji 
Type: Update 
Category: BHD 
Subject: Coil driver test failed for S2100619-v1 

Good catch. It turned out that the both + and - side of the output stages for CH2 were oscillating at ~600kHz. If I use a capacitance sticks to touch arbitrarily around the components, it stops their oscillation and they stay calm.
It means that the phase margin becomes small while the circuit starts up.

I decided to increase the capacitances C6 and C20 (WIMA 150pF) to 330pF (WIMA FPK2 100V) and the oscillation was tamed. 220pF didn't stop them. After visually checked the signal behavior with an oscilloscope, the unit was passed to Anchal for the TF test.

The modification was also recorded in the DCC S2100619

Attachment 1: PXL_20211217_001735762.jpg  1.340 MB  | Hide | Hide all | Show all
PXL_20211217_001735762.jpg
Attachment 2: PXL_20211217_001719345.jpg  1.230 MB  | Show | Hide all | Show all
Attachment 3: PXL_20211217_005344828.jpg  238 kB  | Hide | Hide all | Show all
PXL_20211217_005344828.jpg
Attachment 4: PXL_20211217_010131027.PORTRAIT.jpg  4.314 MB  | Show | Hide all | Show all
Attachment 5: PXL_20211217_011423823.jpg  1.027 MB  | Hide | Hide all | Show all
PXL_20211217_011423823.jpg
Attachment 6: HAMA_Driver_V4.pdf  1.234 MB  | Show | Hide all | Show all
ELOG V3.1.3-