We have completed modifications and testing of the HAM Coil driver D1100687 units with serial numbers listed below. The DCC tree reflects these changes and tests (Run/Acq modes transfer functions).
SERIAL # |
TEST result |
S2100609 |
PASS |
S2100611 |
PASS |
S2100613 |
PASS |
S2100615 |
PASS |
S2100617 |
PASS |
S2100619 |
FAIL (CH2 phase) |
S2100621 |
PASS |
S2100623 |
PASS |
S2100625 |
PASS |
S2100627 |
PASS |
S2100629 |
PASS |
S2100631 |
PASS |
S2100633 |
Waiting for more components |
S2101649** |
PASS |
S2101651** |
PASS |
S2101653** |
PASS |
S2101655** |
PASS |
** A fix had to be done on the DC power supply for these. The units' regulated power boards were not connected to the raw DC power, so the cabling had to be modified accordingly.
Further, Paco fixed the two even serial number units (S2101648, S211650) that failed the test. The issues were minor soldering mistakes that were easily resolved. |