Entry  Fri Dec 10 15:59:23 2021, Paco, Update, BHD, Finished Coil driver (even serial number) units tests dc_fail.jpg
    Reply  Thu Dec 16 12:21:16 2021, Anchal, Update, BHD, Coil driver test failed for S2100619-v1 D1100687_S2100619-v1_TF_CH2_Not_Matching.pdf
       Reply  Thu Dec 16 17:41:12 2021, Koji, Update, BHD, Coil driver test failed for S2100619-v1 6x
    Reply  Thu Dec 16 15:32:59 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests 
       Reply  Thu Dec 16 17:57:17 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests 
       Reply  Mon Dec 20 14:10:56 2021, Anchal, Update, BHD, All coil drivers ready to be used, modified and tested 
Message ID: 16499     Entry time: Fri Dec 10 15:59:23 2021     Reply to this: 16512   16514
Author: Paco 
Type: Update 
Category: BHD 
Subject: Finished Coil driver (even serial number) units tests 

[Paco, Anchal]

We have completed modifications and testing of the HAM Coil driver D1100687 units with serial numbers listed below. The DCC tree reflects these changes and tests (Run/Acq modes transfer functions).

SERIAL # TEST result
S2100608 PASS
S2100610 PASS
S2100612 PASS
S2100614 PASS
S2100616 PASS
S2100618 PASS
S2100620 PASS
S2100622 PASS
S2100624 PASS
S2100626 PASS
S2100628 PASS
S2100630 PASS
S2100632 PASS
S2101648** FAIL (Ch1, Ch3 run mode)
S2101650** FAIL (Ch3 run mode)
S2101652** PASS
S2101654** PASS

** A fix had to be done on the DC power supply for these. The units' regulated power boards were not connected to the raw DC power, so the cabling had to be modified accordingly (see Attachment #1)