40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Fri Dec 10 15:59:23 2021, Paco, Update, BHD, Finished Coil driver (even serial number) units tests
|
Thu Dec 16 12:21:16 2021, Anchal, Update, BHD, Coil driver test failed for S2100619-v1
|
Thu Dec 16 17:41:12 2021, Koji, Update, BHD, Coil driver test failed for S2100619-v1 6x
|
Thu Dec 16 15:32:59 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests
|
Thu Dec 16 17:57:17 2021, Anchal, Update, BHD, Finished Coil driver (odd serial number) units tests
|
Mon Dec 20 14:10:56 2021, Anchal, Update, BHD, All coil drivers ready to be used, modified and tested
|
|
Message ID: 16499
Entry time: Fri Dec 10 15:59:23 2021
Reply to this: 16512
16514
|
Author: |
Paco |
Type: |
Update |
Category: |
BHD |
Subject: |
Finished Coil driver (even serial number) units tests |
|
|
[Paco, Anchal]
We have completed modifications and testing of the HAM Coil driver D1100687 units with serial numbers listed below. The DCC tree reflects these changes and tests (Run/Acq modes transfer functions).
SERIAL # |
TEST result |
S2100608 |
PASS |
S2100610 |
PASS |
S2100612 |
PASS |
S2100614 |
PASS |
S2100616 |
PASS |
S2100618 |
PASS |
S2100620 |
PASS |
S2100622 |
PASS |
S2100624 |
PASS |
S2100626 |
PASS |
S2100628 |
PASS |
S2100630 |
PASS |
S2100632 |
PASS |
S2101648** |
FAIL (Ch1, Ch3 run mode) |
S2101650** |
FAIL (Ch3 run mode) |
S2101652** |
PASS |
S2101654** |
PASS |
** A fix had to be done on the DC power supply for these. The units' regulated power boards were not connected to the raw DC power, so the cabling had to be modified accordingly (see Attachment #1) |
|
|