I went through the optics list (in the BHD procurement google spreadsheet) and summarized how to build them.
The red ones are what we need to purchase. Because of the strange height of the LMR mounts, the post needs to have none half-integer inch heights.
They need to be designed as the usual SS posts are not designed to be vac compatible (not because of the material but the design like screw hole venting).
We also need to check how many clean forks we have.
-> The components were ordered except for the custom posts.
ssome partssss
Name |
Optic |
Mount |
Mount OH |
Post |
Post OH |
Fork / Base |
Base OH |
Total Height |
Notes |
POP_SM5 |
Previous POYM1 / 2" Y1-2037-0 |
LMR2V Thorlabs |
1.36 |
Custom Post |
4.14 |
SS Fork |
0 |
5.5 |
|
POP_SM4 |
New CM254-750-E03 Thorlabs |
LMR1V Thorlabs |
0.87 |
Newport 9953+PLS-T238 |
3.88 |
BA1V / BA2V |
0.75 |
5.5 |
|
BSOL1 |
New 2" VIS BB2-E02 |
LMR2V Thorlabs |
1.36 |
Custom Post |
4.14 |
SS Fork |
0 |
5.5 |
|
ITMYOL1 |
New 2" VIS BB2-E02 |
LMR2V Thorlabs |
1.36 |
Custom Post |
4.14 |
SS Fork |
0 |
5.5 |
|
ITMYOL2 |
New 2" VIS BB2-E02 |
LMR2V Thorlabs |
1.36 |
Custom Post |
4.14 |
SS Fork |
0 |
5.5 |
|
SRMOL1 |
New 2" VIS BB2-E02 |
LMR2V Thorlabs |
1.36 |
Custom Post |
4.14 |
SS Fork |
0 |
5.5 |
|
ASL |
LA1779-C Thorlabs or KPX217AR.33 Newport |
LMR2V Thorlabs |
1.36 |
Custom Post |
4.14 |
SS Fork |
0 |
5.5 |
|
GRY_SM1 |
Y2-2037-0 (in hand) |
DLC |
|
DLC Post |
|
DLC Fork |
|
5.5 |
|
BHDBS |
CVI (In hand) |
DLC |
2 |
DLC Post |
|
DLC Fork |
|
5.5 |
(3" post for BHD) |
LO3 |
Lambda (in hand) |
POLARIS-K1-2AH Thorlabs |
1 |
Custom Post |
4.5 |
SS Fork |
0 |
5.5 |
(3" post for BHD) |
LO4 |
Lambda (in hand) |
POLARIS-K1-2AH Thorlabs |
1 |
Custom Post |
4.5 |
SS Fork |
0 |
5.5 |
(3" post for BHD) |
AS3 |
Lambda (in hand) |
POLARIS-K1-2AH Thorlabs |
1 |
Custom Post |
4.5 |
SS Fork |
0 |
5.5 |
(3" post for BHD) |
OMC1R3 |
Y1-1025-45P (in hand) |
POLARIS-K1-2AH Thorlabs |
1 |
Custom Post |
4.5 |
SS Fork |
0 |
5.5 |
(3" post for BHD) |
OMC1R4 |
Y1-1025-45P (in hand) |
POLARIS-K1-2AH Thorlabs |
1 |
Custom Post |
4.5 |
SS Fork |
0 |
5.5 |
(3" post for BHD) |
OMC2R3 |
Y1-1025-45P (in hand) |
POLARIS-K1-2AH Thorlabs |
1 |
Custom Post |
4.5 |
SS Fork |
0 |
5.5 |
(3" post for BHD) |
OMC2R4 |
Y1-1025-45P (in hand) |
POLARIS-K1-2AH Thorlabs |
1 |
Custom Post |
4.5 |
SS Fork |
0 |
5.5 |
(3" post for BHD) |
|
|
|
|
|
|
|
|
|
|
OMC1R1 |
Y1-1025-45P (in hand) |
LMR1V Thorlabs |
0.87 |
Custom Post |
4.63 |
SS Fork |
0 |
5.5 |
(3.13" post for BHD) |
OMC2R1 |
NB1-K14 Thorlabs |
LMR1V Thorlabs |
0.87 |
Custom Post |
4.63 |
SS Fork |
0 |
5.5 |
(3.13" post for BHD) |
|