Entry  Fri Oct 8 17:33:13 2021, Hang, Update, SUS, More PRM L2P measurements Screenshot_2021-10-08_17-30-52.png
    Reply  Mon Oct 11 11:13:04 2021, rana, Update, SUS, More PRM L2P measurements 
    Reply  Mon Oct 11 13:59:47 2021, Hang, Update, SUS, More PRM L2P measurements prm_l2p_tf_meas_white.pdfprm_l2p_tf_meas_opt.pdfprm_l2p_fisher_vs_data_white_vs_opt.pdfprm_l2p_Pxx_evol_v2.pdf
Message ID: 16389     Entry time: Mon Oct 11 11:13:04 2021     In reply to: 16388
Author: rana 
Type: Update 
Category: SUS 
Subject: More PRM L2P measurements 

For the oplev, there are DQ channels you can use so that its possible to look back in the past for long measurements. They have names like PERROR