40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Fri Mar 19 19:15:13 2021, Jon, Update, CDS, c1auxey assembly
|
Thu Mar 25 12:11:53 2021, Yehonathan, Update, CDS, c1auxey assembly 
|
Thu Mar 25 14:16:33 2021, gautam, Update, CDS, c1auxey assembly
|
Tue Mar 30 17:27:04 2021, Yehonathan, Update, CDS, c1auxey assembly
|
Wed Aug 25 11:48:48 2021, Yehonathan, Update, CDS, c1auxey assembly
|
Mon Sep 13 14:32:25 2021, Yehonathan, Update, CDS, c1auxey assembly
|
Wed Sep 15 11:27:50 2021, Yehonathan, Update, CDS, c1auxey assembly 
|
Thu Apr 15 17:24:08 2021, Jon, Update, CDS, Updated c1auxey wiring plan
|
Mon Apr 19 21:54:55 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan
|
Wed Apr 28 18:56:57 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan
|
Thu Apr 29 16:35:51 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan
|
Thu Apr 29 19:55:45 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan
|
Fri Apr 30 19:18:51 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan
|
Mon May 3 20:36:46 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan
|
Sun May 23 18:28:54 2021, Jon, Update, CDS, Opto-isolator for c1auxey
|
Fri May 28 10:54:59 2021, Jon, Update, CDS, Opto-isolator for c1auxey
|
Thu Jun 3 17:15:17 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey 
|
Thu Jun 3 22:08:00 2021, Koji, Update, CDS, Opto-isolator for c1auxey
|
Fri Jun 4 14:49:23 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Fri Jun 4 17:46:25 2021, unYehonathan, Update, CDS, Opto-isolator for c1auxey
|
Sun Jun 6 16:33:47 2021, Jon, Update, CDS, BI channels on c1auxey
|
Mon Jun 7 13:14:20 2021, Yehonathan, Update, CDS, BI channels on c1auxey
|
Tue Jun 8 11:54:39 2021, Yehonathan, Update, CDS, BI channels on c1auxey
|
Sun Jun 6 03:02:14 2021, Koji, Update, CDS, Opto-isolator for c1auxey
|
Sun Jun 6 12:15:16 2021, Jon, Update, CDS, Opto-isolator for c1auxey
|
Sun Jun 6 15:59:51 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Mon Jun 14 15:31:30 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Tue Jun 15 21:48:55 2021, Koji, Update, CDS, Opto-isolator for c1auxey
|
Wed Jun 16 17:24:29 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Wed Jun 16 20:32:39 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Fri Jul 9 18:35:32 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Mon Jul 12 18:06:25 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Wed Jul 28 12:47:52 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey  
|
Wed Aug 11 12:06:40 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
|
Message ID: 16205
Entry time: Wed Jun 16 17:24:29 2021
In reply to: 16203
Reply to this: 16207
|
Author: |
Yehonathan |
Type: |
Update |
Category: |
CDS |
Subject: |
Opto-isolator for c1auxey |
|
|
I updated the wiring diagram according to Koji's suggestion. According to the isolator manual, this configuration requires that the isolator input be configured as PNP.
Additionally, when the switch in the coil driver is open the LED in the isolator is signaling an on-state. Therefore, we might need to configure the Acromag to invert the input.
There are the Run/Aquire channels that we might need to add to the wiring diagram. If we do need to read them using slow channels, we will have to pull them up like the EnableMon channels to use them like in the wiring diagram. |
|