40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Fri Mar 19 19:15:13 2021, Jon, Update, CDS, c1auxey assembly
|
Thu Mar 25 12:11:53 2021, Yehonathan, Update, CDS, c1auxey assembly 
|
Thu Mar 25 14:16:33 2021, gautam, Update, CDS, c1auxey assembly
|
Tue Mar 30 17:27:04 2021, Yehonathan, Update, CDS, c1auxey assembly
|
Wed Aug 25 11:48:48 2021, Yehonathan, Update, CDS, c1auxey assembly
|
Mon Sep 13 14:32:25 2021, Yehonathan, Update, CDS, c1auxey assembly
|
Wed Sep 15 11:27:50 2021, Yehonathan, Update, CDS, c1auxey assembly 
|
Thu Apr 15 17:24:08 2021, Jon, Update, CDS, Updated c1auxey wiring plan
|
Mon Apr 19 21:54:55 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan
|
Wed Apr 28 18:56:57 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan
|
Thu Apr 29 16:35:51 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan
|
Thu Apr 29 19:55:45 2021, Yehonathan, Update, CDS, Updated c1auxey wiring plan
|
Fri Apr 30 19:18:51 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan
|
Mon May 3 20:36:46 2021, Yehonathan, Jon, Update, CDS, Updated c1auxey wiring plan
|
Sun May 23 18:28:54 2021, Jon, Update, CDS, Opto-isolator for c1auxey
|
Fri May 28 10:54:59 2021, Jon, Update, CDS, Opto-isolator for c1auxey
|
Thu Jun 3 17:15:17 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey 
|
Thu Jun 3 22:08:00 2021, Koji, Update, CDS, Opto-isolator for c1auxey
|
Fri Jun 4 14:49:23 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Fri Jun 4 17:46:25 2021, unYehonathan, Update, CDS, Opto-isolator for c1auxey
|
Sun Jun 6 16:33:47 2021, Jon, Update, CDS, BI channels on c1auxey
|
Mon Jun 7 13:14:20 2021, Yehonathan, Update, CDS, BI channels on c1auxey
|
Tue Jun 8 11:54:39 2021, Yehonathan, Update, CDS, BI channels on c1auxey
|
Sun Jun 6 03:02:14 2021, Koji, Update, CDS, Opto-isolator for c1auxey
|
Sun Jun 6 12:15:16 2021, Jon, Update, CDS, Opto-isolator for c1auxey
|
Sun Jun 6 15:59:51 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Mon Jun 14 15:31:30 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Tue Jun 15 21:48:55 2021, Koji, Update, CDS, Opto-isolator for c1auxey
|
Wed Jun 16 17:24:29 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Wed Jun 16 20:32:39 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Fri Jul 9 18:35:32 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Mon Jul 12 18:06:25 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
Wed Jul 28 12:47:52 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey  
|
Wed Aug 11 12:06:40 2021, Yehonathan, Update, CDS, Opto-isolator for c1auxey
|
|
Message ID: 16166
Entry time: Fri May 28 10:54:59 2021
In reply to: 16154
Reply to this: 16178
|
Author: |
Jon |
Type: |
Update |
Category: |
CDS |
Subject: |
Opto-isolator for c1auxey |
|
|
I have received the opto-isolator needed to complete the new c1auxey system. I left it sitting on the electronics bench next to the Acromag chassis.
Here is the manufacturer's wiring manual. It should be wired to the +15V chassis power and to the common return from the coil driver, following the instructions herein for NPN-style signals. Note that there are two sets of DIP switches (one on the input side and one on the output side) for selecting the mode of operation. These should all be set to "NPN" mode. |
|
|