40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu May 27 14:11:15 2021, Jordan, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring CoM_to_Clamp.PNGCoM_to_Clamp_2.PNG
    Reply  Tue Jun 1 14:26:23 2021, Jordan, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring CoM_to_Clamp_Updated.PNG
       Reply  Wed Jun 2 01:08:57 2021, Koji, Update, SUS, CoM to Clamping Point Measurement for 3" Adapter Ring 
Message ID: 16165     Entry time: Thu May 27 14:11:15 2021     Reply to this: 16169
Author: Jordan 
Type: Update 
Category: SUS 
Subject: CoM to Clamping Point Measurement for 3" Adapter Ring 

The current vertical distance between the CoM and the wire clamping point on the 3" Ring assembly is 0.33mm. That is the CoM is .33 mm below the clamping point of the wire. I took the clamping point to be the top edge of the wire clamp piece. see the below attachments.

I am now modifying the dumbell mechanism at the bottom of the ring to move the CoM to the target distance of 1.1mm.

Attachment 1: CoM_to_Clamp.PNG  669 kB  Uploaded Thu May 27 15:13:47 2021  | Hide | Hide all
CoM_to_Clamp.PNG
Attachment 2: CoM_to_Clamp_2.PNG  708 kB  Uploaded Thu May 27 15:13:57 2021  | Hide | Hide all
CoM_to_Clamp_2.PNG