Message ID: 16136
Entry time: Wed May 12 16:53:59 2021
In reply to: 16135
Reply to this: 16137
|
Author: |
Koji |
Type: |
Update |
Category: |
SUS |
Subject: |
Mass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units |
|
|
No, this is the property of the suspension assembly. The mass says 10kg