40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Feb 24 22:13:47 2021, Jon, Update, CDS, Planning document for front-end testing 
    Reply  Fri Mar 5 17:48:25 2021, Jon, Update, CDS, Front-end testing image_67203585.JPGimage_67216641.JPGimage_17185537.JPG
       Reply  Tue Mar 9 16:52:47 2021, Jon, Update, CDS, Front-end testing image_72192707.JPG
          Reply  Tue Mar 16 16:27:22 2021, Jon, Update, CDS, Front-end testing 
             Reply  Tue Mar 16 19:04:20 2021, gautam, Update, CDS, Front-end testing 
             Reply  Fri Mar 19 18:14:56 2021, Jon, Update, CDS, Front-end testing image_72192707_(1).JPGimage_50412545.JPG
                Reply  Wed Mar 24 19:02:21 2021, Jon, Update, CDS, Front-end testing 
                   Reply  Mon Mar 29 17:55:50 2021, Jon, Update, CDS, Front-end testing 
                      Reply  Tue Mar 30 18:21:34 2021, Jon, Update, CDS, Front-end testing 
                      Reply  Tue Apr 6 07:19:11 2021, Jon, Update, CDS, New SimPlant cymac 
                         Reply  Tue Apr 6 11:13:01 2021, Jon, Update, CDS, FE testing 
                            Reply  Sat Apr 10 08:51:32 2021, Jon, Update, CDS, I/O Chassis Assembly 
                               Reply  Thu Apr 29 10:51:35 2021, Jon, Update, CDS, I/O Chassis Assembly 
                                  Reply  Tue May 4 07:38:36 2021, Jon, Update, CDS, I/O Chassis Assembly Screen_Shot_2021-05-03_at_4.16.06_PM.png
                                     Reply  Tue May 11 16:29:55 2021, Jon, Update, CDS, I/O Chassis Assembly Screen_Shot_2021-05-11_at_3.03.42_PM.png
                                        Reply  Tue May 11 17:43:09 2021, Koji, Update, CDS, I/O Chassis Assembly 
                                           Reply  Fri May 28 11:16:21 2021, Jon, Update, CDS, Front-End Assembly and Testing c1bhd.pnggds_tp.pngteststand.jpegbench_supply.jpeg
                                              Reply  Sun Jun 6 08:42:05 2021, Jon, Update, CDS, Front-End Assembly and Testing c1bhd.png16bit_dacs.pngmyricom.png
                                                 Reply  Tue Jun 22 16:53:01 2021, Ian MacMillan, Update, CDS, Front-End Assembly and Testing 
                                                    Reply  Thu Jun 24 17:32:52 2021, Ian MacMillan, Update, CDS, Front-End Assembly and Testing C1-SU2_Channel_Responses.pdfC1-BHD_Channel_Responses.pdfCDS_Channel_Test.zip
                                                       Reply  Fri Jun 25 14:06:10 2021, Jon, Update, CDS, Front-End Assembly and Testing test_stand.JPG
                         Reply  Sat Apr 10 11:56:14 2021, Jon, Update, CDS, 40m LSC simPlant model x1lsp_main.png
                            Reply  Tue Apr 13 16:24:38 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model 
                               Reply  Mon Apr 19 13:15:20 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model 
                                  Reply  Wed Apr 21 10:03:01 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model Overview.png
                                     Reply  Wed Apr 21 11:01:37 2021, Rana, Update, CDS, 40m LSC simPlant model 
                                     Reply  Fri Apr 23 15:52:19 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model Plant_framework.pdfSimple_Plant.pdfControls.pdf
                                        Reply  Sun Apr 25 21:21:02 2021, rana, Update, CDS, SUS simPlant model 
                                           Reply  Tue Apr 27 15:15:17 2021, Ian MacMillan, Update, CDS, SUS simPlant model x1sus_single_plant.pdfx1sup.pdf
                                              Reply  Thu Apr 29 13:41:40 2021, Ian MacMillan, Update, CDS, SUS simPlant model Non-IPC_Plant.pdf
                                                 Reply  Fri Apr 30 12:52:14 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                    Reply  Mon May 3 13:35:12 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                       Reply  Tue May 4 14:55:38 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                          Reply  Wed May 5 15:11:54 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                             Reply  Thu May 6 16:13:24 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                                Reply  Fri May 7 11:19:29 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
                                                                   Reply  Wed May 12 13:06:15 2021, Ian MacMillan, Update, CDS, SUS simPlant model SimplePlant_SingleContr.pdfx1sup_isolated.pdfX1SUP_ISOLATED_GDS_TP.pngX1SUP_ISOLATED_C1_SUS_SINGLE_PLANT_Plant_POS_Mod.png
                                                                      Reply  Fri May 21 09:44:52 2021, Ian MacMillan, Update, CDS, SUS simPlant model Transfer_Function_of_Damped_Harmonic_Oscillator.pdf
                                                                         Reply  Fri May 21 14:36:20 2021, Ian MacMillan, Update, CDS, SUS simPlant model Plant_Mod_TF.pdf
                                                                            Reply  Thu Jun 3 13:06:47 2021, Ian MacMillan, Update, CDS, SUS simPlant model SingleSusPlantTF.pdfSUS_PLANT_TF.zip
                                                                               Reply  Mon Jun 7 17:49:19 2021, Ian MacMillan, Update, CDS, SUS simPlant model SingleSusPlantTF.pdfTF_Graph_Code.zip
                                                                                  Reply  Wed Jun 9 13:50:48 2021, Ian MacMillan, Update, CDS, SUS simPlant model SingleSusPlantTF.pdf
                                                                                     Reply  Tue Jun 15 11:46:40 2021, Ian MacMillan, Update, CDS, SUS simPlant model x1sup_isolated-6-15-v1.pdfC1_SUS_SINGLE_PLANT-6-15-v1.pdf
                                                                                     Reply  Wed Jun 30 14:09:26 2021, Ian MacMillan, Update, CDS, SUS simPlant model SingleSusPlantTF.pdfPlant_TF_Test.zip
                                                                                        Reply  Mon Aug 23 15:25:59 2021, Ian MacMillan, Update, CDS, SUS simPlant model SimPlantStateSpace.zip
Message ID: 16081     Entry time: Fri Apr 23 15:52:19 2021     In reply to: 16059     Reply to this: 16084
Author: Ian MacMillan 
Type: Update 
Category: CDS 
Subject: 40m LSC simPlant model 

I have attached the framework that I am using for the full system. Plantframework.pdf has the important aspects that I will be changed. Right now I am trying to keep it mostly as is, but I have disconnected the Optic Force Noise and hope to disconnect the Suspension Position Noise. The Optic Force Noise Block is additive to the signal so eliminating it from the system should make it less realistic but simpler. It can be added back easily by reconnecting it.

The next step is adding my plant response, which is simply the transfer function and measurement from the last post. These should be inserted in the place of the red TM_RESP in the model.

The TM_RESP block takes in a vector of dimension 12 and returns a vector of dimension 6. The confusing part is that the block does not seem to do anything. it simply passes the vector through with no changes. I'm not sure why this is the case and I am looking for documentation to explain it but haven't found anything. As to how a 12 vector turns into a 6 vector I am also lost. I will probably just disconnect everything but the x position.

I tried to just throw in my model (see Simple_Plant.pdf) and see what happened but the model would not let me add built-in blocks to the model. This is weird because all the blocks that I am adding are part of the basic library. My guess is that this mode will only accept blocks from the CDL library. I will either need to change my blocks to be made from blocks in the CDL library or maybe I can pass the signal out of the plant framework model then into my model then back to the plant framework model. I think this is just a Matlab thing that I don't know about yet. (Jon probably knows)

I have also attached an image of the controls model for reference. It looks like a mess but I'm sure there is a method. I won't get lost in going through it just assume it works... for now.

The next question I have been asking is how do I show that the system works. When anchal and I made a python simulation of the system, we tested it by seeing the evolution of the degrees of freedom over time given some initial conditions. We could see the pendulum propagating and some of the coupling between the DOFs. This is a fast and dirty way to check if everything is working and should be easy to add. I simply recorded the POS signal and graph it over time. Once we get to a state-space model we can test it by taking the transfer function, but since our plant is literally already just a transfer function there isn't much of a point yet.

Also, I need to add color to my Simple_Plant.pdf model because it looks really boring :(

Attachment 1: Plant_framework.pdf  41 kB  Uploaded Fri Apr 23 16:53:52 2021  | Show | Show all
Attachment 2: Simple_Plant.pdf  31 kB  Uploaded Fri Apr 23 17:23:33 2021  | Show | Show all
Attachment 3: Controls.pdf  408 kB  Uploaded Fri Apr 23 17:25:50 2021  | Show | Show all
ELOG V3.1.3-