40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 16004     Entry time: Wed Apr 7 13:07:03 2021
Author: Jordan 
Type: Update 
Category: SUS 
Subject: CoM on 3"->2" Adapter Ring for SOS 

Adding the chamfer around the edge of the optic ring did not change the center of mass relative to the plane from the suspension wires.

The CoM was .0003" away from the plane. Adding the chamfer moved it closer by .0001". See the attached photo.

I've also attached the list of the Moments of Inertia of the SOS Assembly.

Attachment 1: CoM_with_Chamfer.png  905 kB  Uploaded Wed Apr 7 14:09:20 2021  | Hide | Hide all | Show all
CoM_with_Chamfer.png
Attachment 2: Moments_of_Inertia.PNG  31 kB  Uploaded Wed Apr 7 14:55:20 2021  | Show | Hide all | Show all
ELOG V3.1.3-