Subject: CoM on 3"->2" Adapter Ring for SOS 

Adding the chamfer around the edge of the optic ring did not change the center of mass relative to the plane from the suspension wires.

The CoM was .0003" away from the plane. Adding the chamfer moved it closer by .0001". See the attached photo.

I've also attached the list of the Moments of Inertia of the SOS Assembly.

Attachment 1: CoM_with_Chamfer.png  905 kB  Uploaded Wed Apr 7 14:09:20 2021  | Show | Show all
Attachment 2: Moments_of_Inertia.PNG  31 kB  Uploaded Wed Apr 7 14:55:20 2021  | Show | Show all