Wed Feb 24 22:13:47 2021, Jon, Update, CDS, Planning document for front-end testing
|
Fri Mar 5 17:48:25 2021, Jon, Update, CDS, Front-end testing  
|
Tue Mar 9 16:52:47 2021, Jon, Update, CDS, Front-end testing
|
Tue Mar 16 16:27:22 2021, Jon, Update, CDS, Front-end testing
|
Tue Mar 16 19:04:20 2021, gautam, Update, CDS, Front-end testing
|
Fri Mar 19 18:14:56 2021, Jon, Update, CDS, Front-end testing 
|
Wed Mar 24 19:02:21 2021, Jon, Update, CDS, Front-end testing
|
Mon Mar 29 17:55:50 2021, Jon, Update, CDS, Front-end testing
|
Tue Mar 30 18:21:34 2021, Jon, Update, CDS, Front-end testing
|
Tue Apr 6 07:19:11 2021, Jon, Update, CDS, New SimPlant cymac
|
Tue Apr 6 11:13:01 2021, Jon, Update, CDS, FE testing
|
Sat Apr 10 08:51:32 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Thu Apr 29 10:51:35 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Tue May 4 07:38:36 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Tue May 11 16:29:55 2021, Jon, Update, CDS, I/O Chassis Assembly
|
Tue May 11 17:43:09 2021, Koji, Update, CDS, I/O Chassis Assembly
|
Fri May 28 11:16:21 2021, Jon, Update, CDS, Front-End Assembly and Testing   
|
Sun Jun 6 08:42:05 2021, Jon, Update, CDS, Front-End Assembly and Testing  
|
Tue Jun 22 16:53:01 2021, Ian MacMillan, Update, CDS, Front-End Assembly and Testing
|
Thu Jun 24 17:32:52 2021, Ian MacMillan, Update, CDS, Front-End Assembly and Testing  
|
Fri Jun 25 14:06:10 2021, Jon, Update, CDS, Front-End Assembly and Testing
|
Sat Apr 10 11:56:14 2021, Jon, Update, CDS, 40m LSC simPlant model
|
Tue Apr 13 16:24:38 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model
|
Mon Apr 19 13:15:20 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model
|
Wed Apr 21 10:03:01 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model
|
Wed Apr 21 11:01:37 2021, Rana, Update, CDS, 40m LSC simPlant model
|
Fri Apr 23 15:52:19 2021, Ian MacMillan, Update, CDS, 40m LSC simPlant model  
|
Sun Apr 25 21:21:02 2021, rana, Update, CDS, SUS simPlant model
|
Tue Apr 27 15:15:17 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Thu Apr 29 13:41:40 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Fri Apr 30 12:52:14 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Mon May 3 13:35:12 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Tue May 4 14:55:38 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Wed May 5 15:11:54 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Thu May 6 16:13:24 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Fri May 7 11:19:29 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Wed May 12 13:06:15 2021, Ian MacMillan, Update, CDS, SUS simPlant model   
|
Fri May 21 09:44:52 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Fri May 21 14:36:20 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Thu Jun 3 13:06:47 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Mon Jun 7 17:49:19 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Wed Jun 9 13:50:48 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
Tue Jun 15 11:46:40 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Wed Jun 30 14:09:26 2021, Ian MacMillan, Update, CDS, SUS simPlant model 
|
Mon Aug 23 15:25:59 2021, Ian MacMillan, Update, CDS, SUS simPlant model
|
|
Message ID: 15979
Entry time: Tue Mar 30 18:21:34 2021
In reply to: 15976
|
Author: |
Jon |
Type: |
Update |
Category: |
CDS |
Subject: |
Front-end testing |
|
|
Progress today:
Outside Internet access for FE test stand
This morning Jordan and I ran an 85-foot Cat 6 Ethernet cable from the campus network switch in the office area (on the ligo.caltech.edu domain) to the FE test stand near 1X6. This is to allow the test-stand subnet to be accessed for remote testing, while keeping it invisible to the parallel Martian subnet.
Successful RTCDS model compilation on new FEs
The clone of the chiara:/home/cds disk completed overnight. Today I installed the disk in the chiara clone. The NFS mounts (/opt/rtcds, /opt/rtapps ) shared with the other test-stand machines mounted without issue.
Next, I attempted to open the shared Matlab executable (/cvs/cds/caltech/apps/linux64/matlab/bin/matlab ) and launch Simulink. The existing Matlab license (/cvs/cds/caltech/apps/linux64/matlab/licenses/license_chiara_865865_R2015b.lic ) did not work on this new machine, as they are machine-specific, so I updated the license file. I linked this license to my personal license, so that the machine license for the real chiara would not get replaced. The original license file is saved in the same directory with a *.bak postfix. If this disk is ever used in the real chiara machine, this file should be restored. After the machine license was updated, Matlab and Simulink loaded and allowed model editing.
Finally, I tested RTCDS model compilation on the new FEs using the c1lsc model as a trial case. It encountered one path issue due to the model being located at /opt/rtcds/userapps/release/isc/c1/models/isc/ instead of /opt/rtcds/userapps/release/isc/c1/models/ . This seems to be a relic of the migration of the 40m models from the SVN to a standalone git repo. This was resolved by simply symlinking to the expected location:
$ sudo ln -s /opt/rtcds/userapps/release/isc/c1/models/isc/c1lsc.mdl /opt/rtcds/userapps/release/isc/c1/models/c1lsc.mdl
The model compilation then succeeded:
controls@c1bhd$ cd /opt/rtcds/caltech/c1/rtbuild/release
controls@c1bhd$ make clean-c1lsc
Cleaning c1lsc...
Done
controls@c1bhd$ make c1lsc
Cleaning c1lsc...
Done
Parsing the model c1lsc...
Done
Building EPICS sequencers...
Done
Building front-end Linux kernel module c1lsc...
make[1]: Warning: File 'GNUmakefile' has modification time 28830 s in the
future
make[1]: warning: Clock skew detected. Your build may be incomplete.
Done
RCG source code directory:
/opt/rtcds/rtscore/branches/branch-3.4
The following files were used for this build:
/opt/rtcds/caltech/c1/userapps/release/cds/common/src/cdsToggle.c
/opt/rtcds/userapps/release/cds/c1/src/inmtrxparse.c
/opt/rtcds/userapps/release/cds/common/models/FILTBANK_MASK.mdl
/opt/rtcds/userapps/release/cds/common/models/rtbitget.mdl
/opt/rtcds/userapps/release/cds/common/models/SCHMITTTRIGGER.mdl
/opt/rtcds/userapps/release/cds/common/models/SQRT_SWITCH.mdl
/opt/rtcds/userapps/release/cds/common/src/DB2MAG.c
/opt/rtcds/userapps/release/cds/common/src/OSC_WITH_CONTROL.c
/opt/rtcds/userapps/release/cds/common/src/wait.c
/opt/rtcds/userapps/release/isc/c1/models/c1lsc.mdl
/opt/rtcds/userapps/release/isc/c1/models/IQLOCK_WHITENING_TRIGGERING.mdl
/opt/rtcds/userapps/release/isc/c1/models/PHASEROT.mdl
/opt/rtcds/userapps/release/isc/c1/models/RF_PD_WITH_WHITENING_TRIGGERING.mdl
/opt/rtcds/userapps/release/isc/c1/models/UGF_SERVO_40m.mdl
/opt/rtcds/userapps/release/isc/common/models/FILTBANK_TRIGGER.mdl
/opt/rtcds/userapps/release/isc/common/models/LSC_TRIGGER.mdl
Successfully compiled c1lsc
***********************************************
Compile Warnings, found in c1lsc_warnings.log:
***********************************************
[warnings suppressed]
As did the installation:
controls@c1bhd$ make install-c1lsc
Installing system=c1lsc site=caltech ifo=C1,c1
Installing /opt/rtcds/caltech/c1/chans/C1LSC.txt
Installing /opt/rtcds/caltech/c1/target/c1lsc/c1lscepics
Installing /opt/rtcds/caltech/c1/target/c1lsc
Installing start and stop scripts
/opt/rtcds/caltech/c1/scripts/killc1lsc
/opt/rtcds/caltech/c1/scripts/startc1lsc
Performing install-daq
Updating testpoint.par config file
/opt/rtcds/caltech/c1/target/gds/param/testpoint.par
/opt/rtcds/rtscore/branches/branch-3.4/src/epics/util/updateTestpointPar.pl
-par_file=/opt/rtcds/caltech/c1/target/gds/param/archive/testpoint_210330_170634.par
-gds_node=42 -site_letter=C -system=c1lsc -host=c1lsc
Installing GDS node 42 configuration file
/opt/rtcds/caltech/c1/target/gds/param/tpchn_c1lsc.par
Installing auto-generated DAQ configuration file
/opt/rtcds/caltech/c1/chans/daq/C1LSC.ini
Installing Epics MEDM screens
Running post-build script
safe.snap exists
We are ready to start building and testing models. |