Author: rana 
Type: Update 
Category: Environment 
Subject: seisBLRMS for the past 3 weeks 
Looks like Chris Wipf's fix of using fclose worked for the NDS client.
The attached plot shows the minute trend RMS - we should put the calibration for these into the .m file
so that the EPICS values are in something useful like microns or microns/sec.

I also now see why Nodus seems really slow with the elog sometimes. When we load a page with an attached
PDF, it runs 'gs' to try to generate the PNG preview. Because its on Solaris it often fails because it
can't find some font. We should probably disable the preview or fix the font issue.
Attachment 1: Untitled.png  170 kB  Uploaded Mon May 18 00:30:43 2009  | Hide | Hide all