Entry  Fri Mar 12 03:08:23 2021, Koji, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM P_20210311_224651.jpgP_20210311_225359.jpg
    Reply  Fri Mar 12 12:32:54 2021, gautam, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM BS_actuator.pdfPRMact.pdf
       Reply  Fri Mar 12 13:01:43 2021, rana, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM 
          Reply  Fri Mar 12 13:48:53 2021, gautam, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM 
    Reply  Thu Mar 25 16:02:15 2021, gautam, Summary, SUS, Repeated measurement of coil Rs & Ls for PRM/BS 
Message ID: 15915     Entry time: Fri Mar 12 13:48:53 2021     In reply to: 15914
Author: gautam 
Type: Summary 
Category: SUS 
Subject: Coil Rs & Ls for PRM/BS/SRM 

I didn't repeat Koji's measurement, but he reports the expected ~3.2mH per coil on all the BS and PRM coils.

Quote:

ugh. sounds bad - maybe a short. I suggest measuring the inductance; thats usually a clearer measurement of coil health