Thu Mar 11 14:27:56 2021, gautam, Update, CDS, timesync issue? 
|
Thu Mar 11 18:46:06 2021, gautam, Update, CDS, cds reboot
|
Fri Mar 12 03:28:51 2021, Koji, Update, CDS, cds reboot
|
Fri Mar 12 11:02:38 2021, gautam, Update, CDS, cds reboot
|
|
Message ID: 15910
Entry time: Fri Mar 12 03:28:51 2021
In reply to: 15905
Reply to this: 15911
|
Author: |
Koji |
Type: |
Update |
Category: |
CDS |
Subject: |
cds reboot |
|
|
I want to emphasize the followings:
- FB's RTC (real-time clock/motherboard clock) is synchronized to NTP time.
- The other RT machines are not synchronized to NTP time.
- My speculation is that the RT machine timestamp is produced from the local RT machine time because there is no IRIG-B signal provided. -> If the RTC is more than 1 sec off from the FB time, the timestamp inconsistency occurs. Then it induces "DC" error.
- For now, we have to use "date" command to match the local RTC time to the FB's time.
- So: If NTP synchronization is properly implemented for the RT machines, we will be free from this silly manual time adjustment.
|