Entry  Fri May 15 17:30:00 2009, rob, Update, LSC, arms, coils, locks armslock_no_int.png
    Reply  Sat May 16 16:20:33 2009, rob, Update, LSC, arms, coils, locks, #2 twoproblems.pngcoil_imbalanceETMY.pngITMXalignment.png
Message ID: 1591     Entry time: Fri May 15 17:30:00 2009     Reply to this: 1592
Author: rob 
Type: Update 
Category: LSC 
Subject: arms, coils, locks 

This is the two arms locked, for an hour.  No integrator in either loop, but from this it looks like ETMY may have a bigger length2angle problem than ETMX.  I'll put some true integrators in the loops and do this again.

 

 

Attachment 1: armslock_no_int.png  27 kB  | Hide | Hide all
armslock_no_int.png
ELOG V3.1.3-