40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu Aug 20 00:21:51 2020, gautam, Update, Electronics, First look at HV coil driver  
|
Sun Aug 23 23:36:58 2020, gautam, Update, Electronics, First look at HV coil driver 
|
Wed Aug 26 16:12:25 2020, gautam, Update, Electronics, Test mass coil current requirements
|
Tue Sep 1 15:39:04 2020, gautam, Update, Electronics, HV coil driver oscillations fixed 
|
Thu Oct 22 11:14:47 2020, gautam, Update, Electronics, HV coil driver packaged into 2U chassis  
|
Thu Oct 22 13:04:42 2020, rana, Update, Electronics, HV coil driver packaged into 2U chassis
|
Thu Oct 22 22:01:53 2020, gautam, Update, Electronics, HV coil driver packaged into 2U chassis 
|
Fri Oct 23 09:03:43 2020, anchal, Update, Electronics, HV coil driver packaged into 2U chassis
|
Thu Nov 12 14:55:35 2020, gautam, Update, Electronics, More systematic noise characterization 
|
Thu Nov 12 15:40:42 2020, Koji, Update, Electronics, More systematic noise characterization
|
Mon Nov 16 00:02:34 2020, rana, Update, Electronics, More systematic noise characterization
|
Wed Jan 20 10:13:06 2021, gautam, Update, Electronics, HV Power supply bypassing    
|
Mon Feb 1 12:30:21 2021, gautam, Update, Electronics, More careful characterization  
|
Wed Feb 10 21:14:03 2021, gautam, Update, Electronics, Production version of the HV coil driver tested   
|
Fri Feb 26 16:31:02 2021, gautam, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
Fri Feb 26 20:20:43 2021, Koji, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
Sat Feb 27 17:25:42 2021, gautam, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
Thu May 20 16:56:21 2021, Koji, Update, Electronics, Production version of the HV coil driver tested with KEPCO HV supplies
|
|
Message ID: 15846
Entry time: Fri Feb 26 16:31:02 2021
In reply to: 15802
Reply to this: 15847
|
Author: |
gautam |
Type: |
Update |
Category: |
Electronics |
Subject: |
Production version of the HV coil driver tested with KEPCO HV supplies |
|
|
Koji asked me to test the production version of the coil driver with the KEPCO HV supplies. See Attachment #1 for the results. For comparison, I've added a single trace from the measurements made with the HP supplies. I continue to see excess noise with the KEPCO supplies. Note that in the production version of the board that was tested, there are a pair of 10uF bypass capacitors on the board for the HV supply lines. It is possible that one or both KEPCO supplies are damaged - one was from the ASY setup and one I found in the little rack next to 1X2. The test conditions were identical to that with the HP supplies (as best as I could make it so). |
|
|