40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Tue Feb 2 17:09:17 2021, yehonathan, Update, BHD, SOS assembly 
|
Tue Feb 2 18:24:54 2021, Koji, Update, BHD, SOS assembly
|
Thu Feb 4 15:14:55 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Feb 16 13:13:39 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Feb 16 15:29:01 2021, Koji, Update, BHD, SOS assembly
|
Tue Feb 16 22:59:36 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Feb 19 12:21:04 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Mar 26 10:25:37 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Apr 6 15:42:57 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Apr 9 20:54:54 2021, Yehonathan, Update, BHD, SOS assembly 
|
Mon Apr 12 17:30:11 2021, Yehonathan, Update, BHD, SOS assembly
|
Mon May 3 16:49:04 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Jun 1 16:17:06 2021, Yehonathan, Update, BHD, SOS assembly
|
Wed Jun 2 01:03:19 2021, Koji, Update, BHD, SOS assembly
|
Fri Jun 18 19:02:00 2021, Yehonathan, Update, BHD, SOS assembly  
|
Fri Jun 18 23:53:08 2021, Koji, Update, BHD, SOS assembly
|
Tue Jun 22 17:05:26 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Jul 27 17:14:18 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Jul 27 20:12:53 2021, Koji, Update, BHD, SOS assembly
|
Mon Jun 28 12:35:19 2021, Yehonathan, Update, BHD, SOS assembly    
|
Tue Jun 29 20:45:52 2021, Yehonathan, Update, BHD, SOS assembly 
|
Thu Jul 1 16:45:25 2021, Yehonathan, Update, BHD, SOS assembly
|
Wed Jul 28 12:00:35 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Sep 23 18:18:07 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Oct 26 10:17:14 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Oct 28 23:13:19 2021, Yehonathan, Update, BHD, SOS assembly   
|
Tue Nov 2 15:02:03 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Nov 2 22:50:30 2021, Koji, Update, BHD, SOS assembly
|
Mon Nov 8 17:22:27 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Nov 9 11:11:37 2021, Yehonathan, Update, BHD, SOS assembly
|
Fri Nov 12 23:47:29 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Nov 16 17:42:46 2021, Yehonathan, Update, BHD, SOS assembly    
|
Tue Nov 16 18:28:53 2021, Koji, Update, BHD, SOS assembly 
|
Wed Nov 24 14:15:15 2021, Yehonathan, Update, BHD, SOS assembly
|
Wed Dec 1 12:57:08 2021, Yehonathan, Update, BHD, SOS assembly 7x
|
Mon Dec 6 18:23:04 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Dec 9 21:57:35 2021, Yehonathan, Update, BHD, SOS assembly 
|
Tue Dec 14 14:02:33 2021, Yehonathan, Update, BHD, SOS assembly 
|
Wed Dec 15 22:09:53 2021, Yehonathan, Update, BHD, SOS assembly
|
Thu Dec 16 18:16:36 2021, Yehonathan, Update, BHD, SOS assembly   
|
Fri Dec 17 17:50:17 2021, Yehonathan, Update, BHD, SOS assembly   
|
Fri Dec 17 19:16:45 2021, Koji, Update, BHD, SOS assembly
|
Fri Dec 17 22:16:07 2021, Yehonathan, Update, BHD, SOS assembly
|
Sat Dec 18 00:56:14 2021, Koji, Update, BHD, SOS assembly
|
Mon Dec 20 13:52:01 2021, Koji, Update, BHD, SOS assembly
|
Mon Dec 20 17:26:13 2021, Yehonathan, Update, BHD, SOS assembly 7x
|
Tue Dec 21 18:04:46 2021, Yehonathan, Update, BHD, SOS assembly
|
Tue Jan 4 18:27:23 2022, Paco, Update, BHD, SOS assembly -- PR3    
|
Wed Jan 5 19:18:06 2022, Yehonathan, Update, BHD, SOS assembly -- AS4  
|
Thu Jan 6 17:00:20 2022, Yehonathan, Update, BHD, SOS assembly -- LO2  
|
Thu Jan 6 17:16:51 2022, Yehonathan, Update, BHD, Using Peek screws/nuts
|
Fri Jan 7 17:59:45 2022, Yehonathan, Update, BHD, SOS assembly -- SR2  
|
Fri Jan 7 18:24:25 2022, Koji, Update, BHD, SOS assembly -- SR2
|
Mon Jan 10 14:00:44 2022, not Koji, Update, BHD, SOS assembly -- SR2
|
Tue Jan 11 09:53:14 2022, not Koji, Update, BHD, SOS assembly -- Peek screws and nuts
|
Thu Jan 13 16:08:00 2022, Yehonathan, Update, BHD, gluing magnets after AS1/4 misfortune
|
Fri Jan 14 17:33:10 2022, Yehonathan, Update, BHD, AS4 resurrection  
|
Wed Jan 19 18:15:34 2022, Yehonathan, Update, BHD, AS1 resurrection   
|
Thu Jan 20 12:10:51 2022, Yehonathan, Update, BHD, AS1 resurrection  
|
Mon Jan 24 17:58:21 2022, Yehonathan, Update, BHD, PR2 Suspension
|
Tue Jan 25 18:37:12 2022, TYehonathan, Update, BHD, PR2 Suspension  
|
Thu Feb 24 18:05:58 2022, Yehonathan, Update, BHD, Re-susspension of AS1 
|
Wed Mar 2 14:02:43 2022, Yehonathan, Update, BHD, Re-susspension of AS1
|
Thu Mar 3 17:09:46 2022, Paco, Update, BHD, Re-susspension of AS1
|
Mon Mar 7 16:56:08 2022, Yehonathan, Update, BHD, Re-susspension of AS1  
|
Mon Mar 7 18:53:16 2022, Koji, Update, BHD, Re-susspension of AS1
|
Tue Mar 8 12:24:13 2022, Yehonathan, Update, BHD, Re-susspension of AS1  
|
Tue Mar 8 19:29:36 2022, Paco, Update, BHD, Re-balance of AS1
|
Wed Mar 9 09:35:26 2022, Paco, Update, BHD, Re-balance of AS1
|
|
Message ID: 15788
Entry time: Tue Feb 2 17:09:17 2021
Reply to this: 15790
|
Author: |
yehonathan |
Type: |
Update |
Category: |
BHD |
Subject: |
SOS assembly |
|
|
I set up a working area on the table next to the south flow bench (see attachment). I also brought in a rolling table for some extra space.
I covered all the working surfaces with a foil from the big roll between 1x3 and 1x4.
I took the SOSs, SOS parts and the OSEMS from the MC2 table to the working area.
I cleaned some LN Allen keys with isopropanol and put them on the working table, please don't take them. |
|
|
|