40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Jan 20 18:07:09 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements before modifications 7x
    Reply  Mon Jan 25 18:18:04 2021, Anchal, Summary, BHD, Satellite Amplifier Transfer Functions and noise D1002818_S2100029_TFandNoiseSpectrum.pdfD1002818_Testing.zip
       Reply  Wed Feb 3 16:27:19 2021, Anchal, Summary, BHD, Satellite Amplifier Transfer Functions and noise After modifications D1002818_S2100029_TFAfterChanges.pdfD1002818_S2100029_OutputNoiseSpecAfterChanges.pdfD1002818_S2100029_InputRefferedNoiseSpecAfterChanges.pdfD1002812_S2100029_After_Modifications_Feb3.jpgAfterChanges.zip
          Reply  Wed Feb 10 11:45:59 2021, Anchal, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications 6x
             Reply  Wed Feb 10 15:07:50 2021, Anchal, Summary, BHD, Satellite Amplifier Output Offset measurements 
                Reply  Wed Feb 10 15:25:45 2021, gautam, Summary, BHD, Satellite Amplifier Output Offset measurements 
                   Reply  Wed Feb 10 17:18:03 2021, Koji, Summary, BHD, Satellite Amplifier Output Offset measurements 
             Reply  Thu Feb 11 11:10:05 2021, Anchal, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications AfterChangesSpectrum_AC.zipD1002818_S2100029_OutputNoiseSpecAfterChanges.pdfD1002818_S2100029_InputRefCurrentNoiseSpecAfterChanges.pdfD1002818_S2100029_InputRefDispNoiseSpecAfterChanges.pdf
                Reply  Thu Feb 11 16:58:52 2021, rana, Summary, BHD, Satellite Amplifier Very Low frequency noise After modifications 
    Reply  Thu Jan 28 12:53:14 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements before modifications D1100117_S2100027_Current_Noise_Spectrum.pdfD1100117_S2100027_Voltage_Noise_Spectrum.pdfD1100117_S2100028_Current_Noise_Spectrum.pdfD1100117_S2100028_Voltage_Noise_Spectrum.pdfSpectrumMeasurement.zip
       Reply  Thu Jan 28 18:04:55 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications D1100117_S2100027_TF.pdfAfterChanges.zip
          Reply  Thu Jan 28 21:44:45 2021, gautam, Summary, BHD, HAM-A Coil Driver measurements After modifications 
             Reply  Fri Jan 29 15:39:30 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications TF and Noise S2100027 D1100687_S2100027_After_Modifications_Jan28.jpgD1100117_S2100027_TF.pdfD1100117_S2100027_Voltage_Noise_Spectrum.pdfD1100117_S2100027_Current_Noise_Spectrum.pdfAfterChanges.zip
                Reply  Tue Feb 2 11:57:46 2021, Anchal, Summary, BHD, HAM-A Coil Driver measurements After modifications TF and Noise S2100028 D1100687_S2100028_After_Modifications_Feb01_2021.jpgD1100117_S2100028_TF.pdfD1100117_S2100028_Voltage_Noise_Spectrum.pdfD1100117_S2100028_Current_Noise_Spectrum.pdfAfterChanges.zip
Message ID: 15787     Entry time: Tue Feb 2 11:57:46 2021     In reply to: 15784
Author: Anchal 
Type: Summary 
Category: BHD 
Subject: HAM-A Coil Driver measurements After modifications TF and Noise S2100028 

I have made the modifications on the other board D1100687 S2100028 as well. The measurements were taken as mentioned in 40m/15784. All conclusions remain the same as 40m/15784. The attached zip file contains all measurement data, before and after the modifications.


Edit Wed Feb 3 16:44:51 2021 :

Added zero modeled noise in the noise spectrum curves. The acquisition mode curves are in agreement with the model. The noise in Run mode is weirdly lower than predicted by zero.

Attachment 1: D1100687_S2100028_After_Modifications_Feb01_2021.jpg  1.343 MB  | Hide | Hide all
D1100687_S2100028_After_Modifications_Feb01_2021.jpg
Attachment 2: D1100117_S2100028_TF.pdf  102 kB  Uploaded Wed Feb 3 16:43:01 2021  | Hide | Hide all
D1100117_S2100028_TF.pdf D1100117_S2100028_TF.pdf D1100117_S2100028_TF.pdf D1100117_S2100028_TF.pdf D1100117_S2100028_TF.pdf
Attachment 3: D1100117_S2100028_Voltage_Noise_Spectrum.pdf  381 kB  Uploaded Wed Feb 3 16:43:19 2021  | Hide | Hide all
D1100117_S2100028_Voltage_Noise_Spectrum.pdf D1100117_S2100028_Voltage_Noise_Spectrum.pdf D1100117_S2100028_Voltage_Noise_Spectrum.pdf D1100117_S2100028_Voltage_Noise_Spectrum.pdf D1100117_S2100028_Voltage_Noise_Spectrum.pdf
Attachment 4: D1100117_S2100028_Current_Noise_Spectrum.pdf  383 kB  Uploaded Wed Feb 3 16:43:52 2021  | Hide | Hide all
D1100117_S2100028_Current_Noise_Spectrum.pdf D1100117_S2100028_Current_Noise_Spectrum.pdf D1100117_S2100028_Current_Noise_Spectrum.pdf D1100117_S2100028_Current_Noise_Spectrum.pdf D1100117_S2100028_Current_Noise_Spectrum.pdf
Attachment 5: AfterChanges.zip  20.638 MB  Uploaded Wed Feb 3 16:44:30 2021
ELOG V3.1.3-