40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Aug 6 00:34:38 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
    Reply  Fri Aug 7 11:23:47 2020, rana, Update, BHD, Monte Carlo Simulations 
       Reply  Mon Aug 10 07:13:00 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
          Reply  Tue Aug 25 05:51:29 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
             Reply  Mon Sep 14 07:50:01 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 10x
                Reply  Fri Oct 16 09:16:37 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
                   Reply  Thu Oct 22 11:48:08 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
                      Reply  Thu Dec 10 14:48:00 2020, Yehonathan, Update, BHD, Monte Carlo Simulations MCMCLance_NoiseBudget_Example.pdfIFO_Check.pdf
                         Reply  Fri Dec 11 09:28:52 2020, rana, Update, BHD, Monte Carlo loop coupling Simulations 
                            Reply  Mon Dec 14 11:09:28 2020, Yehonathan, Update, BHD, Monte Carlo loop coupling Simulations MCMC_LANCE_OLTFs.pdfMCMC_LANCE_OLCoupling2DARM.pdf
                               Reply  Mon Jan 11 16:11:51 2021, Yehonathan, Update, BHD, Monte Carlo loop coupling Simulations MC_LANCE_OLTFs.pdf
                                  Reply  Mon Jan 11 19:10:10 2021, rana, Update, BHD, Monte Carlo loop coupling Simulations 
Message ID: 15734     Entry time: Mon Dec 14 11:09:28 2020     In reply to: 15732     Reply to this: 15758
Author: Yehonathan 
Type: Update 
Category: BHD 
Subject: Monte Carlo loop coupling Simulations 

I spent a few hours monkeying around with the control filters. They are totally made up and also it's my first time trying to design control filters.

The OLTFs of the different length controls are shown in attachment 1.

The open-loop couplings of the DOFS to DARM are shown in attachment 2.

Note that in Lance/Pytickle the convention is that CLTFs are 1/(1 - G). Where G is the OLTF.

Quote:

Cool. Can you give us Bode plots of the open loop gain for each of the 5 length control loops?

 

 

Attachment 1: MCMC_LANCE_OLTFs.pdf  139 kB  | Hide | Hide all | Show all
MCMC_LANCE_OLTFs.pdf
Attachment 2: MCMC_LANCE_OLCoupling2DARM.pdf  124 kB  | Show | Hide all | Show all
ELOG V3.1.3-