Wed Nov 18 22:49:06 2020, gautam, Update, ASC, Some thoughts about AS WFS electronics
|
Sun Nov 22 21:09:37 2020, gautam, Update, ASC, Planned mods for WFS head  
|
Wed Nov 25 18:18:41 2020, gautam, Update, ASC, Planned mods for WFS head 
|
Sat Nov 28 21:44:53 2020, rana, Update, ASC, Planned mods for WFS head
|
Thu Dec 10 22:46:57 2020, gautam, Update, ASC, WFS head assembled 
|
Thu Dec 17 15:23:56 2020, gautam, Update, ASC, WFS head characterization    
|
Wed Nov 25 18:30:23 2020, gautam, Update, ASC, Some thoughts about AS WFS electronics
|
Wed Dec 2 23:07:19 2020, gautam, Update, ASC, Electrical LO signal for AS WFS
|
Thu Dec 3 11:02:35 2020, rana, Update, Electronics, Electrical LO signal for AS WFS
|
Thu Dec 3 13:55:52 2020, Koji, Update, ASC, Electrical LO signal for AS WFS
|
Thu Dec 3 20:38:46 2020, gautam, Update, ASC, Electrical LO signal for AS WFS  
|
Thu Dec 3 21:14:38 2020, Koji, Update, ASC, Electrical LO signal for AS WFS
|
Thu Dec 3 21:44:49 2020, gautam, Update, ASC, Electrical LO signal for AS WFS
|
Fri Dec 4 03:02:40 2020, Koji, Update, ASC, Electrical LO signal for AS WFS
|
Fri Dec 4 22:41:56 2020, gautam, Update, ASC, Freq Gen Box revamp
|
Sat Dec 5 20:44:35 2020, gautam, Update, ASC, Freq Gen Box re-installed 6x
|
Mon Dec 7 12:38:51 2020, gautam, Update, IOO, IMC loop char  
|
Mon Dec 7 22:54:30 2020, gautam, Update, LSC, Modulation depth measurement
|
Sat Jan 16 18:59:44 2021, gautam, Update, LSC, Modulation depth measurement   
|
|
Message ID: 15697
Entry time: Wed Dec 2 23:07:19 2020
In reply to: 15690
Reply to this: 15700
15702
|
Author: |
gautam |
Type: |
Update |
Category: |
ASC |
Subject: |
Electrical LO signal for AS WFS |
|
|
I'm thinking of making some modifications to the RF distribution box in 1X2, so as to have an extra 55 MHz pickoff. Koji already proposed some improvements to the layout in 2015. I've marked up his "Possible Improvement" page of the document in Attachment #1, with my proposed modifications. I believe it will be possible to get 15-16 dBm of signal into a 4 way RF splitter in the quad demod chassis. With the insertion loss of the splitter, we can have 9-10 dBm of LO reaching each demod board, which will then be boosted to +20 dBm by the Teledyne on board. The PE4140 mixer claims to require only -7 dBm of LO signal. So we have quite a bit of headroom here - as long as we limit the RF signal to 0dBm (=0.5 Vpp from the LMH6431 opamp at 55 MHz, we shouldn't be having a much larger signal anyways), we should be just fine with 15 dBm of LO power (which is what we will have after the division into the I and Q paths, and nominal insertion losses in the transmission path). These numbers may be slight overestimates given the possible degradation of the RF amps over the last 10 years, but shouldn't be a show-stopper.