Entry  Thu Aug 6 00:34:38 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
    Reply  Fri Aug 7 11:23:47 2020, rana, Update, BHD, Monte Carlo Simulations 
       Reply  Mon Aug 10 07:13:00 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
          Reply  Tue Aug 25 05:51:29 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
             Reply  Mon Sep 14 07:50:01 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 10x
                Reply  Fri Oct 16 09:16:37 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
                   Reply  Thu Oct 22 11:48:08 2020, Yehonathan, Update, BHD, Monte Carlo Simulations 8x
                      Reply  Thu Dec 10 14:48:00 2020, Yehonathan, Update, BHD, Monte Carlo Simulations MCMCLance_NoiseBudget_Example.pdfIFO_Check.pdf
                         Reply  Fri Dec 11 09:28:52 2020, rana, Update, BHD, Monte Carlo loop coupling Simulations 
                            Reply  Mon Dec 14 11:09:28 2020, Yehonathan, Update, BHD, Monte Carlo loop coupling Simulations MCMC_LANCE_OLTFs.pdfMCMC_LANCE_OLCoupling2DARM.pdf
                               Reply  Mon Jan 11 16:11:51 2021, Yehonathan, Update, BHD, Monte Carlo loop coupling Simulations MC_LANCE_OLTFs.pdf
                                  Reply  Mon Jan 11 19:10:10 2021, rana, Update, BHD, Monte Carlo loop coupling Simulations 
Message ID: 15539     Entry time: Tue Aug 25 05:51:29 2020     In reply to: 15512     Reply to this: 15569
Author: Yehonathan 
Type: Update 
Category: BHD 
Subject: Monte Carlo Simulations 

I re-plotted the MCMC results as semi-transparent lines so that probable lines stick out.

This also reveals what is behind the extreme sparsity in the aLIGO simulation results (In the previous post).

There seem to be some bi-stability/phase transition/whatever in the aLIGO simulation. The aLIGO transfer functions are very sensitive to one or more of the DOFs. Not sure which yet.

Attachment 1: MICH_AplusMCMC.pdf  46 kB  Uploaded Tue Aug 25 06:52:14 2020  | Hide | Hide all
MICH_AplusMCMC.pdf
Attachment 2: PRCL_AplusMCMC.pdf  46 kB  Uploaded Tue Aug 25 06:52:30 2020  | Hide | Hide all
PRCL_AplusMCMC.pdf
Attachment 3: SRCL_AplusMCMC(1).pdf  45 kB  Uploaded Tue Aug 25 06:53:09 2020  | Hide | Hide all
SRCL_AplusMCMC(1).pdf
Attachment 4: OMC_Diff_AplusMCMC.pdf  49 kB  Uploaded Tue Aug 25 06:53:52 2020  | Hide | Hide all
OMC_Diff_AplusMCMC.pdf
Attachment 5: OMC_Comm_AplusMCMC.pdf  46 kB  Uploaded Tue Aug 25 06:54:12 2020  | Hide | Hide all
OMC_Comm_AplusMCMC.pdf
Attachment 6: OMC_Angle_Yaw_AplusMCMC.pdf  50 kB  Uploaded Tue Aug 25 06:54:40 2020  | Hide | Hide all
OMC_Angle_Yaw_AplusMCMC.pdf
Attachment 7: OMC_Angle_Pitch_AplusMCMC.pdf  50 kB  Uploaded Tue Aug 25 06:54:59 2020  | Hide | Hide all
OMC_Angle_Pitch_AplusMCMC.pdf
Attachment 8: Main_Laser_RIN_AplusMCMC.pdf  47 kB  Uploaded Tue Aug 25 06:55:25 2020  | Hide | Hide all
Main_Laser_RIN_AplusMCMC.pdf