Fri Jul 10 01:25:28 2020, gautam, Update, LSC, Locking notes
|
Fri Jul 10 15:26:28 2020, gautam, Update, LSC, MC2 coils need DC balancing? 
|
Sat Jul 11 18:24:30 2020, Koji, Update, LSC, MC2 coils need DC balancing?
|
Sun Jul 12 02:42:01 2020, gautam, Update, LSC, Locking (on rossa)
|
Mon Jul 13 11:36:08 2020, rana, Update, LSC, MC2 coils need DC balancing?
|
|
Message ID: 15474
Entry time: Mon Jul 13 11:36:08 2020
In reply to: 15468
|
Author: |
rana |
Type: |
Update |
Category: |
LSC |
Subject: |
MC2 coils need DC balancing? |
|
|
- if IMC REFL is not increasing, I don't think its a mis-alignment. Usually, REFL is a more sensitive indicator of alignment than TRANS since its usually near zero. Maybe the MC2 TRANS PD is not centered or doesn't have enough lens action.
- to reduce the DC load on MC2, you could have a slow releif drive the ETMs and DC and minimize LSC-MCL
|