40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Jun 4 20:54:40 2020, gautam, Update, SUS, MC1 Slow Bias issues 
    Reply  Thu Jun 4 21:32:00 2020, Koji, Update, SUS, MC1 Slow Bias issues 
       Reply  Thu Jun 25 15:11:00 2020, gautam, Update, SUS, MC1 coil driver resistance quartered MCF.pdf
          Reply  Sun Jun 28 15:30:52 2020, gautam, Update, SUS, MC1 sat-box de-lidded 20200628T144138.jpg
             Reply  Sun Jun 28 16:29:58 2020, rana, Update, SUS, MC1 sat-box de-lidded 
                Reply  Sun Jun 28 17:36:35 2020, gautam, Update, SUS, MC1 sat-box de-lidded 
                   Reply  Mon Jun 29 11:55:46 2020, gautam, Update, SUS, MC1 sat-box de-lidded SatBoxSwap.jpg
                      Reply  Mon Jun 29 20:30:53 2020, Koji, Update, SUS, MC1 sat-box de-lidded 
Message ID: 15435     Entry time: Sun Jun 28 16:29:58 2020     In reply to: 15434     Reply to this: 15436
Author: rana 
Type: Update 
Category: SUS 
Subject: MC1 sat-box de-lidded 

does the FLIR have an option to export image with a colorbar?

How about just leave the lid open? or more open? I don't know what else can be done in the near term. Maybe swap with the SRM sat box to see if that helps?

ELOG V3.1.3-