Message ID: 15381     Entry time: Mon Jun 8 12:49:07 2020     In reply to: 15380     Reply to this: 15382
Author: Koji 
Type: Update 
Category: BHD 
Subject: Astigmatism and scattering plots 

Can you describe the mode matching  in terms of the total MM? Is MM_total = sqrt(MM_vert * MM_horiz)?

ELOG V3.1.3-