40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 15339     Entry time: Wed May 20 18:45:22 2020
Author: Hang 
Type: Update 
Category: BHD 
Subject: BHD mode-matching study--corner plot & adjustment requirement 

As Rana suggested, we present the scattering plot of the AS path mode matching for various variables. The plot is for the AS path, Plan 2 (whose params we summarize at the end of this entry).

In the corner plot, we color-coded each realization according to the mode matching. We use (purple, olive, grey) for (MM>0.99, 0.98<MM<=0.99, MM<=0.98), respectively. From the plot, we can see that it is most sensitive to the RoC of AS1. The plot also shows that we can compensate for some of the MM errors if we adjust the distance between AS1-AS3 (note that AS2 is a flat mirror). The telescope is quite robust to other errors.

The compensation requirement is further shown in the second plot. To correct for the 1% RoC error of AS1, we typically need to adjust AS1-AS3 distance by ~ 1 cm (if we want to go back to MM=1; the window for >0.99 MM spans also about 1 cm). This should be doable because the nominal distance between AS1-AS3 is 115 cm. 

The story for plan1 is similar and thus not shown here. 

==============================================================

AS path plan2 nominal params:

label     z (m)     type             parameters  
-----     -----     ----             ----------  
SRMAR          0    flat mirror      none:     
AS1       0.7192    curved mirror    ROC: 2.5000 
AS2       1.2597    flat mirror      none:     
AS3       1.8658    curved mirror    ROC: -0.5000
AS4       2.5822    curved mirror    ROC: 0.6000  
OMCBS1    3.3271    flat mirror      none:   
Attachment 1: AS_MM_scat2.pdf  720 kB  | Show | Show all
Attachment 2: AS_MM_adj2.pdf  99 kB  | Show | Show all
ELOG V3.1.3-