Thu Apr 2 15:53:01 2020, gautam, Update, ASC, PRMI 1f locked for collecting feedforward data
|
Fri Apr 3 17:15:53 2020, gautam, Update, ASC, POP angular FF filters trained and tested    
|
Mon Apr 6 12:26:07 2020, rana, Update, ASC, POP angular FF filters trained and tested
|
Mon Apr 6 16:46:40 2020, gautam, Update, ASC, POP angular FF filters trained and tested
|
|
Message ID: 15291
Entry time: Thu Apr 2 15:53:01 2020
Reply to this: 15296
|
Author: |
gautam |
Type: |
Update |
Category: |
ASC |
Subject: |
PRMI 1f locked for collecting feedforward data |
|
|