Entry  Tue Apr 28 16:36:24 2009, rob, HowTo, Locking, setting the RF CARM demod phase CARM_phases_REFL.pdfSRCL_phases_REFL.pdf
    Reply  Tue Apr 28 17:51:13 2009, rob, HowTo, Locking, setting the RF CARM demod phase XARM_phases_POX.pdfCARM_phases_POX.pdf
Message ID: 1529     Entry time: Tue Apr 28 16:36:24 2009     Reply to this: 1530
Author: rob 
Type: HowTo 
Category: Locking 
Subject: setting the RF CARM demod phase 

To set the demod phase for RF CARM, sensed at REFL2 (REFL 166I), it suffices to set the demod phase for REFL2 to be the optimal phase for controlling SRCL in a no-arm state.