Thu Feb 27 17:50:36 2020, gautam, Update, PSL, c1psl setup setup  
|
Fri Feb 28 08:05:22 2020, gautam, Update, PSL, c1psl setup setup
|
Fri Feb 28 10:04:41 2020, gautam, Update, PSL, c1psl setup setup
|
Fri Feb 28 19:37:18 2020, gautam, Update, PSL, New c1psl installed
|
|
Message ID: 15231
Entry time: Thu Feb 27 17:50:36 2020
Reply to this: 15234
|
Author: |
gautam |
Type: |
Update |
Category: |
PSL |
Subject: |
c1psl setup setup |
|
|
[many people]
in prep for the install tomorrow, we did the following:
- Install the c1psl Supermicro in the 1X2 rack (Attachment 1). To make room we removed the anti-image filter and mounted it on the OMC rack.
- Set up a local workstation (monitor+mouse+keyboard) for the Supermicro so we can do some local testing (Attachment 2).
- Clear up the immediate area around the 1X1/1X2 rack, setup a cart for the Acromag.
- Make sure there are sufficient adaptor boards cables (DB37, DB15, DB9, DB25, ethernet) etc available at the cart.
- Label cables, connect on Acromag chassis end (Attachment 3).
- Keep some large (A3) printouts of the channel mapping handy by the cart.
- made sure we have open fuse-able DIN rail connectors for +/-15 V DC and +/-24 V DC for the Acromag box (we are waiting on some thinner gauge cabling for the 24V supply, once that arrives, we will power the box from the Sorensens. For now, they are powered by bench supplies on the cart).
- made sure c1psl1 (still this name for the Supermicro) is ssh-able.
Barring objections, tomorrow (Friday 28 Feb 2020) morning I will commence the switch (I still want to work on the IFO tonight). |
|
|
|
|
|
|