Tue Nov 26 17:07:41 2019, gautam, Update, LSC, POX / POY calibration 
|
Tue Nov 26 18:16:08 2019, rana, Update, LSC, POX / POY calibration
|
Wed Nov 27 12:16:52 2019, gautam, Update, LSC, ITMX and ITMY OSEMs with low and high circulating power 
|
Wed Nov 27 13:14:02 2019, rana, Update, LSC, ITMX and ITMY OSEMs with low and high circulating power
|
Wed Nov 27 16:10:29 2019, gautam, Update, LSC, AOM reconnected
|
|
Message ID: 15050
Entry time: Tue Nov 26 18:16:08 2019
In reply to: 15049
Reply to this: 15051
|
Author: |
rana |
Type: |
Update |
Category: |
LSC |
Subject: |
POX / POY calibration |
|
|
...maybe the opto-mechanical CARM plant is changing as a function of the CARM offset...
Quote: |
Even assuming 50% error in the calibration factors, it's hard to explain the swing of TRX/TRY when the CARM offset is brought to zero.
- The increase in (admittedly in-loop) CARM noise as the offset is reduced still seems to me to be correlated with the buildup of IR power in the arm cavities.
|
|