Message ID: 14937     Entry time: Fri Oct 4 00:30:31 2019     In reply to: 14934     Reply to this: 14940
Author: gautam 
Type: Update 
Category: General 
Subject: Make the Jenne-laser setup fiber-coupled 

I think the metric of interest here is the consistency of the AC transimpedance of the proposed new "Reference PD" (= fiber coupled NF1611) vs the old reference (free space NF1611), since everything will be calibrated against that.

Quote:

Something still looks very wrong -- the PD is supposed to be flat out to 1GHz, and physical units pending, need food.