40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Sep 6 16:38:24 2019, aaron, Update, ALARM, Alarm noise from smart-ups machine under workstation? 
    Reply  Fri Sep 6 18:08:29 2019, rana, Update, Computers, Alarm noise from smart-ups machine under workstation? 
       Reply  Thu Sep 12 09:49:07 2019, gautam, Update, Computers, control rm wkstns shutdown IMG_7943.JPG
          Reply  Mon Sep 30 11:42:36 2019, aaron, Update, Computers, control rm wkstns shutdown 
             Reply  Wed Oct 2 20:45:18 2019, rana, Update, Computers, rossa revival 
                Reply  Thu Oct 3 21:50:22 2019, rana, Update, Computers, rossa revival 
                Reply  Mon Oct 28 18:55:06 2019, rana, Update, Computers, rossa revival 
                   Reply  Wed Jan 22 16:38:01 2020, rana, Update, Computers, rossa revival 
                      Reply  Wed Jul 1 18:16:09 2020, gautam, Update, Computers, rossa re-re-revival MCacc.pdf
                         Reply  Sun Jul 5 16:14:41 2020, rana, Update, Computers, rossa re-re-revival 
                         Reply  Sun Jul 5 18:39:57 2020, rana, Update, Computers, rossa: printer 
                            Reply  Mon Jul 6 00:37:28 2020, gautam, Update, Computers, rossa: lib symlink 
                               Reply  Mon Jul 6 12:43:02 2020, rana, Update, Computers, rossa: lib symlink 
                                  Reply  Mon Jul 6 12:51:41 2020, gautam, Update, Computers, rossa: resolvconf installed 
                                     Reply  Wed Jul 8 22:50:33 2020, gautam, Update, Computers, rossa: more symlinks 
                                  Reply  Thu Jul 9 16:16:20 2020, gautam, Update, Computers, rossa: graphics driver issues? 
                                     Reply  Sat Jul 11 00:10:22 2020, gautam, Update, Computers, rossa: more developmental work 
                                        Reply  Mon Jul 13 11:33:18 2020, rana, Update, Computers, rossa: more developmental work 
                                           Reply  Mon Jul 13 12:37:05 2020, gautam, Update, Computers, rossa: more developmental work 
Message ID: 14913     Entry time: Mon Sep 30 11:42:36 2019     In reply to: 14873     Reply to this: 14925
Author: aaron 
Type: Update 
Category: Computers 
Subject: control rm wkstns shutdown 

I booted Rossa in rescue mode; though I see no errors on bootup, I still see the same error ("a problem has occurred") after boot, and a prompt to logout. I powered rossa off/on (single short press of power button), no change.

Booting in debug mode, I see that the error occurs when mounting /cvs/cds, with the error

[FAILED] Failed to mount /cvs/cds.
See `systemctl status cvs-cds.mount` for details.
[DEPEND] Dependency failed for Remote File System

Which is odd, because when I boot in recovery mode, is mounts /cvs/cds successfully. 

I booted in emergency mode by adding to the boot command

systemd.unit=emergency.target

but didn't have the appropriate root password to troubleshoot further (the usual two didn't work).