40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 14892     Entry time: Tue Sep 17 23:43:34 2019
Author: Koji 
Type: Summary 
Category: CDS 
Subject: Acromag logic checker 

For the investigation of the latch logic issue for the CARM CM board, I have made the LED logic checkers with DB breakout boards. They require the pull up voltage supply of +15V because the acromag digital out is a open corrector (well... open "source") output.

The logic from Pin1 to Pin16 of DB37 can be monitored. The DB15 connector is only for monitoring the latch enable logic.

What Gautam and I found with the logic outputs was that the latch logic works fine but occasionally we found that the top 2 bits and the bottom 4bit were processed independently.

Attachment 1: digital_checker.pdf  25 kB  Uploaded Wed Sep 18 03:31:16 2019  | Hide | Hide all | Show all
digital_checker.pdf
Attachment 2: IMG_8914.JPG  4.373 MB  Uploaded Wed Sep 18 03:31:16 2019  | Show | Hide all | Show all
ELOG V3.1.3-