Author: aaron 
Type: HowTo 
Category: CDS 
Subject: WFS discussion, restarting CDS 

As suggested, I ran the script cds/rebootC1LSC.sh

I got a timeout error when the script tried closing the PSL shutter ('C1:AUX-PSL_ShutterRqst' not found), but Rana and I closed the shutter before leaving last night. c1sus is down, so the script found no route to host c1sus; I'm thinking I need to reset c1sus for the script to run completely. Nonetheless, c1lsc was rebooted, which crashed c1ioo and left the c1lsc FE all red (probably because c1sus wasn't restarted).

 