Fri Jul 19 17:42:58 2019, gautam, Update, General, rossa Xdisp bricked
|
Sat Jul 20 11:24:04 2019, gautam, Update, General, rossa bricked
|
Sun Jul 21 22:16:34 2019, rana, Update, General, rossa Xdisp bricked
|
Mon Jul 22 21:04:40 2019, rana, Update, Computers, making rossa great again
|
Tue Aug 6 14:12:02 2019, yehonathan, Update, Computers, making rossa great again
|
|
Message ID: 14799
Entry time: Mon Jul 22 21:04:40 2019
In reply to: 14794
Reply to this: 14831
|
Author: |
rana |
Type: |
Update |
Category: |
Computers |
Subject: |
making rossa great again |
|
|
- copied over /etc/fstab lines from pianosa sothat the NFS mounts work correctly
- added symlinks so that the NFS dirs mount in the right dirs
- installed Opera browser
- symlink libsasl2.so.3 -> libsasl2.so.2 and now DTT runs and can get data now and in the past
- DTT can natively produce PDF so you don't have to take screen caps of your camera phone and make a chalk drawing of that anymore
- sitemap/MEDM is working
- after editing fonts.alias as detailed in Thorne wiki, I ran 'sudo xset fp rehash' to get MEDM to notice new fonts. MEDM Scalable fonts are back!!
- installed Grace and now dataviewer works
- ndscope not running: yum install ndscope breaks because it can't find a couple of python34 packages

- tested that AWGGUI also runs and puts in real sine waves
|
|
|