Wed Jul 10 14:57:01 2019, Koji, Summary, CDS, Channel recipe for iscaux upgrade 
|
Thu Jul 11 12:42:35 2019, gautam, Summary, CDS, P2 interface board
|
Thu Jul 11 13:08:36 2019, Chub, Summary, CDS, P2 interface board
|
Thu Jul 11 13:09:22 2019, gautam , Summary, CDS, P2 interface board
|
Sat Jul 20 11:57:39 2019, gautam, Summary, CDS, P2 interface board
|
Thu Jul 18 00:51:52 2019, Koji, Summary, CDS, iscaux electronics modifications 
|
Thu Jul 18 22:34:40 2019, Koji, Summary, CDS, iscaux electronics modifications
|
|
Message ID: 14785
Entry time: Sat Jul 20 11:57:39 2019
In reply to: 14747
|
Author: |
gautam |
Type: |
Summary |
Category: |
CDS |
Subject: |
P2 interface board |
|
|
The boards arrived. I soldered on a DIN96 connector, and tested that the goemetry will work. It does . The only constraint is that the P2 interface board has to be installed before the P1 interface is installed. Next step is to confirm that the pin-mapping is correct. The pin mapping from the DIN96 connector to the DB15 was also verified.