40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Tue Jun 25 15:32:16 2019, gautam, Update, IOO, PMC and IMC locked again, some MEDM maintenance
|
Wed Jun 26 10:55:13 2019, aaron, Update, IOO, PMC and IMC locked again, some MEDM maintenance
|
Wed Jun 26 11:11:40 2019, Milind, Update, IOO, PMC and IMC locked again, some MEDM maintenance
|
Wed Jun 26 18:28:24 2019, rana, Update, IOO, PMC and IMC locked again, some MEDM maintenance
|
Sun Jun 30 22:21:07 2019, Milind, Update, IOO, PMC and IMC locked again, some MEDM maintenance
|
Sun Jun 30 23:52:09 2019, Koji, Update, IOO, PMC and IMC locked again, some MEDM maintenance
|
Mon Jul 1 11:02:05 2019, Milind, Update, IOO, PMC and IMC locked again, some MEDM maintenance
|
Tue Jul 9 10:37:42 2019, Milind, Update, IOO, keyed psl crate, unstick.py, pmc autolocker code- working
|
Mon Jul 15 14:53:40 2019, Milind, Update, IOO, keyed psl crate, unstick.py
|
Mon Jul 15 18:55:05 2019, gautam, Update, IOO, Megatron hard-rebooted
|
Wed Jul 24 12:24:43 2019, Milind, Update, IOO, unstick.py and ifotest
|
|
Message ID: 14737
Entry time: Tue Jul 9 10:37:42 2019
In reply to: 14711
Reply to this: 14761
14805
|
Author: |
Milind |
Type: |
Update |
Category: |
IOO |
Subject: |
keyed psl crate, unstick.py, pmc autolocker code- working |
|
|
Today, Gautam keyed the C1PSL crate and we got to test my unstick.py code. It seems to be working fine. Remarks:
- Gautam moved the unstick.py code to /opt/rtcds/caltech/c1/scripts/cds. Therefore, the steps to run this code are now:
- cd /opt/rtcds/caltech/c1/scripts/cds
- python unstick.py c1psl (for the c1psl machine)
- There is now a sleepTime global variable in the code which defines the amount of delay between successive channel toggles. We set this to 1ms and it took the code around 3s to run.
- Gautam was curious to see if this would work even if we set the sleepTime parameter to 0 but decided that that could be tested the next time something was keyed.
- I still need to add the signal handling thing to this code.
Following this, we tested my PMC autolocker code. The code ran for about a minute before achieveing lock. Remarks:
- Gautam moved my code (pmc_autolocker.py and autolocker_config.yaml) to /cvs/cds/rtcds/caltech/c1/scripts/PSL/PMC/ . Therefore, the steps to run this code are now:
- cd /cvs/cds/rtcds/caltech/c1/scripts/PSL/PMC/
- python pmc_autolocker.py (check code or use --help to see what the command line arguments do which is only for when you wanna override the details in the .yaml file)
- Gautam suggested that I add some delay between succesive steps of DC output adjust so that it locks quickly. I'll do that ASAP. For now, it works.
|