Fri Apr 10 19:09:48 2009, Jenne, Update, PSL, PMC LO Calibration 
|
Sat Apr 11 00:45:41 2009, Yoichi, Update, PSL, PMC LO Calibration
|
Sun Apr 12 19:27:20 2009, rana, Update, PSL, PMC LO Calibration
|
Mon Apr 13 08:59:57 2009, steve, Update, PSL, mixers on order
|
|
Message ID: 1473
Entry time: Sat Apr 11 00:45:41 2009
In reply to: 1471
Reply to this: 1475
1477
|
Author: |
Yoichi |
Type: |
Update |
Category: |
PSL |
Subject: |
PMC LO Calibration |
|
|
Quote: |
I then changed the RF Output Adjust slider in increments of 0.5, and measured the peak-to-peak values on the scope. In the table and on the plots, I've taken into account the 12dB attenuation. i.e I actually measured 964mV, so 964mV*10^.6 = 3838mV.
|
3.8Vpp is about 16dBm.
The mixer for the PMC demodulator is level 23. So 16dBm is insufficient.
What is the level of the new mixer Steve ordered ? 13 ? |