40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu May 23 15:37:30 2019, Milind, Update, Cameras, Simulation enhancements and performance of contour detection 6x
|
Sat May 25 20:29:08 2019, Milind, Update, Cameras, Simulation enhancements and performance of contour detection    
|
Wed Jun 12 22:02:04 2019, Milind, Update, Cameras, Simulation enhancements  
|
Mon Jun 17 14:36:13 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking
|
Tue Jun 18 22:54:59 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking
|
Tue Jun 25 00:25:47 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 8x
|
Tue Jun 25 22:14:10 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking
|
Thu Jun 27 20:48:22 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking   
|
Thu Jul 4 18:19:08 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking  
|
Mon Jul 8 17:52:30 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking
|
Tue Jul 9 22:13:26 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
|
Wed Jul 10 22:32:38 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking
|
Mon Jul 15 14:09:07 2019, Milind, Update, Cameras, CNN LSTM for beam tracking  
|
Fri Jul 19 16:47:06 2019, Milind, Update, Cameras, CNNs for beam tracking || Analysis of results 7x
|
Sat Jul 20 12:16:39 2019, gautam, Update, Cameras, CNNs for beam tracking || Analysis of results
|
Sat Jul 20 14:43:45 2019, Milind, Update, Cameras, CNNs for beam tracking || Analysis of results   
|
Wed Jul 24 20:05:47 2019, Milind, Update, Cameras, CNNs for beam tracking || Tales of desperation
|
Thu Jul 25 00:26:47 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
|
Mon Jun 17 22:19:04 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker
|
Mon Jul 1 20:18:01 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker
|
Tue Jul 2 12:30:44 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker
|
Sun Jul 7 17:54:34 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker
|
Tue Jun 25 23:52:37 2019, Milind, Update, Cameras, Simulation enhancements
|
Mon Jul 1 20:11:34 2019, Milind, Update, Cameras, Simulation enhancements
|
|
Message ID: 14715
Entry time: Mon Jul 1 20:18:01 2019
In reply to: 14680
Reply to this: 14717
|
Author: |
Milind |
Type: |
Update |
Category: |
Computer Scripts / Programs |
Subject: |
PMC autolocker |
|
|
I've begun working on this. Steps to complete:
- Convert the autolocker to python. Test that it works.
- Run the script with different settings of the servo gain adjust and DC output adjust parameters and obtain a plot of the average time of lock to determine what the best settings of the aforementioned parameters are.
Quote: |
As Rana asked me to in the last meeting, I dug through the elogs to determine what had become of the previous autolockers. I stumbled upon this elog by Rana from before Gautam cleaned up the medm screen. Out of curiosity, I ran the autolocker script using the instructions in Rana's elog. I did this a total of 5 times and could lock the PMC 3 times fairly quickly. I attempted to decipher the details of the code but did not make much headway owing to my unfamiliarity with the language. From what I could make out from the medm screen while the autolocker was running, it appeared to be the same method as that in this elog. I will take a look at it again tomorrow. However, I intend to spend most of tomorrow working on preprocessing the data, developing the CNN script and then the simulation.
Quote: |
- I shall also begin working on a script to autolock the PMC based on what Rana showed me on Monday. I will also take a look at the the contents of this elog and try to pick up from there. I hope to make significant progress by the next lab meeting.
|
|
|