Grabbed the PMC data
I went to set up the spectrum analyzer measurements through GPIB, but inadvertently deleted the contents of ~/Agilent/netgpibdata/ (made a soft link in my folder, decided I wanted it gone but rm'ed instead of unlink). I copied what I think was in that folder back (from /opt/rtcds/caltech/c1/scripts/general/labutils/netgpibdata).
Again, the spectra are:
- R-- PMC TRANS PD into SR560 with G=2 DC coupled, no filtering
- A-- PDH IF into SR560 with G=2, DC coupled, no filtering
- B-- PMC PZT HV MON into SR560 with G=2, AC coupled, no filtering
I recorded the three spectra with the following parameters:
- Three separate spans:
- 10 Hz to 150 kHz
- 100 to 550 kHz
- 500 kHz to 2.5 MHz
- bwSpanRatio = 0.1 %
- averages: 10
- number of points: 801
- spec type: noise (PSD units)
I then ran AGmeasure with the above parameters in the yaml, with the rest following the defaults in AgilentTemplate.yaml. I saved the data in /users/aaron/40m/data/PMC/190617/
Looks like the header contains all of the parameters, so I shouldn't have trouble distinguishing the spectra. I didn't get the instant plotting working, but the data seem to be there.
I'm still having trouble getting the data from the oscilloscope. I'm not sure why the tektronix scrips I've used before aren't working, I'm checking it now.
update: Grabbed the data, the issue was just using the wrong IP address.
|