40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Jun 4 00:17:15 2019, gautam, Update, BHD, Preliminary BHD calculations LOreqs.pdf
    Reply  Thu Jun 6 18:49:22 2019, gautam, Update, BHD, Preliminary BHD calculations darkPortScatter.pdfOMCbackscatter.pdfdirectScatter.pdf
       Reply  Wed Jul 3 11:47:36 2019, gautam, Update, BHD, PRC filtering PRCfiltering.pdf
          Reply  Wed Jul 31 09:41:12 2019, gautam, Update, BHD, OMC cavity geometry paramSpaceHeatMap.pdf
             Reply  Wed Jul 31 17:57:35 2019, Koji, Update, BHD, OMC cavity geometry 
             Reply  Fri Aug 23 10:01:14 2019, gautam, Update, BHD, OMC cavity geometry - some more modeling modeContentComparison.pdfOMCtransComparison.pdf
       Reply  Tue Aug 6 15:52:06 2019, gautam, Update, BHD, Preliminary BHD calculations OMCbackscatter.pdf
Message ID: 14658     Entry time: Thu Jun 6 18:49:22 2019     In reply to: 14652     Reply to this: 14722   14833
Author: gautam 
Type: Update 
Category: BHD 
Subject: Preliminary BHD calculations 

Summary:

I did some more calculations based on our discussions at the meeting yesterday. Posting preliminary results here for comments.

Details:

Attachment #1 - Schematic illustration for the scattering scenarios. For all three scenarios, we would like for the scattered field to be lower than unsqueezed vacuum (safety factor to be debated).

Attachment #2 - Requirements on a fraction \epsilon_{\mathrm{bs}} = 10 \, \mathrm{ppm} of the counter-propagating resonant mode of the OMC scattering back into the antisymmetric port, as a function of RIN and phase noise on this field (y-axis) and amount of field (depends on the amount of contrast defect light which can become resonant in the counter propagating mode). I don't encode any frequency dependence here.

Attachment #3 - Requirements on the direct scatter from the arm cavity resonant field (assumed to dominate any contribution from the PRC) onto the OMC DCPDs, for some assumed phase noise (y-axis) and fraction of the field that makes it onto the OMC DCPDs. This is a pretty stringent requirement. But the probability is low (it is the product of three presumably small numbers, (i) probablity of the beam scattering out of the TEM00 mode, (ii) BRDF of the scattering surface, (iii) probability of scattering back towards the DCPDs), so maybe feasible? I didn't model any RIN on this field, which would be an additional noise term to contend with. The range of the y-axis was chosen because I think these are reasonable amplitudes for chamber wall  / other scattering surface motion at acoustic frequencies.

Attachment 1: darkPortScatter.pdf  439 kB  Uploaded Thu Jun 6 19:50:19 2019  | Show | Show all
Attachment 2: OMCbackscatter.pdf  39 kB  Uploaded Thu Jun 6 19:55:52 2019  | Show | Show all
Attachment 3: directScatter.pdf  31 kB  Uploaded Thu Jun 6 19:56:01 2019  | Show | Show all
ELOG V3.1.3-