40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu May 23 15:37:30 2019, Milind, Update, Cameras, Simulation enhancements and performance of contour detection 6x
|
Sat May 25 20:29:08 2019, Milind, Update, Cameras, Simulation enhancements and performance of contour detection    
|
Wed Jun 12 22:02:04 2019, Milind, Update, Cameras, Simulation enhancements  
|
Mon Jun 17 14:36:13 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking
|
Tue Jun 18 22:54:59 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking
|
Tue Jun 25 00:25:47 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 8x
|
Tue Jun 25 22:14:10 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking
|
Thu Jun 27 20:48:22 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking   
|
Thu Jul 4 18:19:08 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking  
|
Mon Jul 8 17:52:30 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking
|
Tue Jul 9 22:13:26 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
|
Wed Jul 10 22:32:38 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking
|
Mon Jul 15 14:09:07 2019, Milind, Update, Cameras, CNN LSTM for beam tracking  
|
Fri Jul 19 16:47:06 2019, Milind, Update, Cameras, CNNs for beam tracking || Analysis of results 7x
|
Sat Jul 20 12:16:39 2019, gautam, Update, Cameras, CNNs for beam tracking || Analysis of results
|
Sat Jul 20 14:43:45 2019, Milind, Update, Cameras, CNNs for beam tracking || Analysis of results   
|
Wed Jul 24 20:05:47 2019, Milind, Update, Cameras, CNNs for beam tracking || Tales of desperation
|
Thu Jul 25 00:26:47 2019, Milind, Update, Cameras, Convolutional neural networks for beam tracking 
|
Mon Jun 17 22:19:04 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker
|
Mon Jul 1 20:18:01 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker
|
Tue Jul 2 12:30:44 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker
|
Sun Jul 7 17:54:34 2019, Milind, Update, Computer Scripts / Programs, PMC autolocker
|
Tue Jun 25 23:52:37 2019, Milind, Update, Cameras, Simulation enhancements
|
Mon Jul 1 20:11:34 2019, Milind, Update, Cameras, Simulation enhancements
|
|
Message ID: 14635
Entry time: Thu May 23 15:37:30 2019
Reply to this: 14638
|
Author: |
Milind |
Type: |
Update |
Category: |
Cameras |
Subject: |
Simulation enhancements and performance of contour detection |
|
|
- Implemented image level noise for simulation. Added only uniform random noise.
- Implemented addition of uniform random noise to any sinusoidal motion of beam spot.
- Implemented motion along y axis according to data in "power_spectrum" file.
- Impelemented simulation of random motion of beam spot in both x and y directions (done previously by Pooja, but a cleaner version).
- Created a video file for 10s with motion of beam spot along the y direction as given by Attachment #1. This was created by mixing four sinusoids at different amplitudes (frequencies (0.1, 0.2, 0.4, 0.8) Hz Amplitudes as fractions of N = 64 (0.1 0.09 0.08 0.09). FPS = 10. Total number of frames = 100 for the sake of convenience. See Attachment #5.
- Following this, I used the thresholding (threshold = 127, chosen arbitrarily), contour detection and centroid computation sequence (see Attachment #6 for results) to obtain the plot in Attachment 2 for the predicted motion of the y coordinate. As is evident, the centering and scale of values obtained are off and I still haven't figured out how to precisely convert from one to another.
- Consequently, as a workaround, I simply normalised the values corresponding to each plot by subtracting the mean in each case and dividing the resulting series of values by their maximum. This resulted in the plots in Attachments 3 and 4 which show the normalised values of y coordinate variation and the error between the actual and predicted values between 0 and 1 respectively.
Things yet to be done:
Simulation:
- I will implement the mean square error function to compute the relativer performance as conditions change.
- I will add noise both to the image and to the motion (meaning introduce some randomness in the motion) to see how the performance, determined by both the curves such as the ones below and the mean square error, changes.
- Following this, I will vary the standard deviation of the beam spot along X and Y directions and try to obtain beam spot motion similar to the video in Attachment #2 of elog post 14632.
- Currently, I have made no effort to carefully tune the parameters associated with contour detection and threshold and have simply used the popular defaults. While this has worked admirably in the case of the simple simulated videos, I suspect much more tweaking will be needed before I can use this on real data.
- It is an easy step to determine the performance of the algorithm for random, circular and other motions of the beam spot. However, I will defer this till later as I do not see any immediate value in this.
- Determine noise threshold. In simulation or with real data: obtain a video where the beam spot is ideally motionless (easy to do with simulated data) and then apply the above approach to the video and study the resulting predicted motion. In simulation, I expect the predictions for a motionless beam spot video (without noise) to be constant. Therefore, I shall add some noise to the video and study the prediction of the algorithm.
- NOTE: the above approach relies on some previous knowledge of what the video data will look like. This is useful in determining which contours to ignore, if any like the four bright regions at the corners in this video.
Real data:
- Obtaining real data and evaluate if the algorithm is succesful in determining contours which can be used to track the beam spot.
- Once the kind of video feed this will be used on is decided, use the data generated from such a feed to determine what the best settings of hyperparameters are and detect the beam spot motion.
- Synchronization of data stream regarding beam spot motion and video.
- Determine the calibration: anglular motion of the optic to beam spot motion on the camera sensor to video to pixel mapping in the frames being processed.
Other approaches:
- Review work done by Gabriele with CNNs, implement it and then compare performance with the above method.
|
|
|
|
|
|
|
|
|
|
|